CORC

浏览/检索结果: 共49条,第1-10条 帮助

已选(0)清除 条数/页:   排序方式:
Effect of Kushen injection in combined with continuing nursing on the patients with instillation therapy after bladder cancer surgery 期刊论文
Journal of Hainan Medical University, 2016, 卷号: Vol.22 No.14, 页码: 140-143
作者:  Rui-Xia Han;  Rui-Min Han;  Li-Kun Chen;  Ming-Juan Liu;  Hai-Ming Du
收藏  |  浏览/下载:13/0  |  提交时间:2019/03/26
The  Seventh  People’s  Hospital  of  Hebei  Province  073000.  Tel:  13731669048  E-mail:  liyat1966@163.com  Foundation  Project:  The  study  was  supported  by  the  Scientific  and  Research  Project  of  Health  Planning  Commission  in  Hebei  Province  with  the  number  of  20150090.  1.  Introduction  Bladder  cancer  is  a  common  malignant  tumor  of  urinary  system  with  early  symptoms  of  painless  hematuria  accompanied  by  urgent  urination  odynuria  frequent  urination  or  dysuria  long  disease  course  poor  prognosis  which  can  severely  affect  the  patients’  living  qualities[1-3].  Currently  surgery  is  a  main  means  for  the  treatment  of  bladder  cancer  but  about  2/3  patients  after  operation  will  relapse  the  instillation  therapy  is  generally  adopted  after  operation  to  reduce  the  recurrence  rate[4-6]  but  the  instillation  therapy  cause  bladder  irritation  symptoms  (BD)  and  will  be  discontinued  usually  due  to  intolerance  in  a  severe  condition[7]  therefore  how  to  alleviate  BD  symptoms  during  the  chemotherapy  period  to  improve  the  living  qualities  has  been  an  urgent  tissue  to  be  resolved.  The  study  is  aimed  to  explore  the  effect  of  Kushen  injection  in  combined  with  continuing  nursing  on  the  patients  with  instillation  therapy  after  bladder  cancer  surgery.  2.  Materials  and  methods  2.1.  Clinical  materials  A  total  of  60  patients  with  bladder  cancer  who  were  admitted  in  Objective:  To  observe  the  effect  of  Kushen  injection  in  combined  with  continuing  nursing  on  the  patients  with  instillation  therapy  after  bladder  cancer  surgery.  Methods:  A  total  of  60  patients  with  bladder  cancer  who  were  admitted  in  our  hospital  from  January  2013  to  January  2015  for  instillation  therapy  were  included  in  the  study  and  were  randomized  into  the  observation  group  and  the  control  group.  The  patients  in  the  two  groups  were  given  routine  THP  instillation  therapy.  On  this  basis  Kushen  injection  Continuing  nursing  Bladder  cancer  Instillation  therapy  Immunological  function  Living  quality  
Solitary skull metastasis as the first symptom of hepatocellular carcinoma: case report and literature review 期刊论文
Neuropsychiatric Disease and Treatment, 2014, 卷号: 10, 页码: 681-686
作者:  Guo, Xieli;  Yin, Jiangliu;  Jiang, Yugang*
收藏  |  浏览/下载:5/0  |  提交时间:2019/12/03
Skull metastasis from hepatocellular carcinoma (HCC) is reported rarely. In addition  solitary skull metastasis as the first symptom of HCC is reported even less. Here  we reported a case of solitary skull metastasis as the first symptom of HCC and reviewed the literature on skull metastasis. A 49-year-old male patient was admitted to Jinjiang Hospital of Quanzhou Medical College with a painless parietal-occipital scalp mass  and he denied any history of hepatic disease. A cranial computed tomography demonstrated a hypervascular enhancement with osteolytic change in the right parietal-occipital region  cranial magnetic resonance imaging indicated a highly enhanced and osteolytic skull tumor  and abdominal computed tomography showed a huge tumor in the liver. The other examinations showed no other metastases. Laboratory data showed no liver dysfunction while hepatitis B surface antigen was positive  and alpha fetal protein level was high. A craniectomy was performed and the mass was totally removed. The histological diagnosis was skull metastasis from HCC. The patient was subsequently treated by transcatheter arterial chemoembolization. In a review of published literature  the incidence of skull metastasis from HCC in the period between 1990 and 2011 has significantly increased. The misdiagnosis rate of skull metastases as the first symptom from HCC was high. Therefore  it is necessary to give each patient with a scalp mass that has invaded the skull a liver ultrasound or computed tomography scan. On the other hand  we found that metastases that occurred in the calvaria site were more frequent than those that occurred in the skull base and facial skeleton. This may be worthy of further investigation in the future.  
黄酮类化合物与α-羟乙基过氧自由基反应的脉冲辐解研究 期刊论文
物理化学学报, 2013
张福根; 周瀚洋; 彭静*; 吴季兰*
收藏  |  浏览/下载:5/0  |  提交时间:2015/11/13
The application of adaptive enhancement algorithm based on gray entropy in mammary gland CR image (EI CONFERENCE) 会议论文
2012 2nd International Conference on Consumer Electronics, Communications and Networks, CECNet 2012, April 21, 2012 - April 23, 2012, Three Gorges, China
Zhang M.-H.; Zhang Y.-Y.
收藏  |  浏览/下载:26/0  |  提交时间:2013/03/25
Mammary gland is composed entirely of soft tissue with approximate density  therefore mammary gland CR medicine radiation image presents a low contrast  and slight difference changes may be a manifestation of tumor  so it is necessary to enhance mammary gland CR image to improve its visual quality in order to meet the demands of doctor's clinical diagnosis. However the general enhancement algorithms over enhance the contrast and noise  due to image details lost  aiming at the defects  a mammary gland CR medicine image adaptive enhancement arithmetic based on image gray entropy is put forward. The arithmetic adapts dizzy image to magnify selected spatial frequency response in order to enhance the edge details of mammary gland CR images. It can adjust weighted factor K according to image gray characteristics namely pixel gray entropy. Experiments results demonstrate that mammary gland CR image enhanced by the algorithm has abundant details and high signal-to-noise ratio  moreover  CR image enhanced has good visual effect. So the method is effective and fit for enhancing CR medical radiation image edge details. 2012 IEEE.  
The application of digital signal processing (DSP) for the real time solving of artillery fire control exterior trajectory (EI CONFERENCE) 会议论文
2012 IEEE 3rd International Conference on Software Engineering and Service Science, ICSESS 2012, June 22, 2012 - June 24, 2012, Beijing, China
Li D.; Guo L. H.
收藏  |  浏览/下载:133/0  |  提交时间:2013/03/25
Study on ultra-light secondary baffle for coaxial two-mirror telescope (EI CONFERENCE) 会议论文
2012 9th IEEE International Conference on Mechatronics and Automation, ICMA 2012, August 5, 2012 - August 8, 2012, Chengdu, China
Zhang L.; Jia X.; Xie P.; Xing L.
收藏  |  浏览/下载:50/0  |  提交时间:2013/03/25
The coaxial two-mirror telescope consists of two mirrors facing each other. Classical two-mirror arrangements are Gregorian and Cassegrain. These systems are usually applied to space telescopes and often have optical baffles to prevent stray light from entering the focal plane. The optical baffles consist of concentric rings suspended between the secondary and the primary mirror. The secondary baffle for a large two-mirror optical system is designed and analyzed in this paper. According to mission of a telescope  the structure should have high stiffness and high reliability and light weight. Compared with invar  aluminum alloy and titanium alloy  carbon fiber composite is currently the best material in terms of weight-to-strength ratio. It also has advantages of high temperature tolerance and low thermal expansion. So carbon fiber composite is chosen as material to meet requirements of the coaxial telescope. In this paper  optimization method based on finite element analysis (FEA) is used for design the secondary baffle. Minimum weight of the baffle is chosen as an objective function. Thicknesses of former tube and vanes are chosen as variables. Analysis results show that the designed secondary baffle has maximum diameter of 180mm  total length of 120mm and weighs 142g. And its fundamental frequency reaches 651Hz. Therefore the baffle has many advantages  such as ultra-light weight  high stiffness and dimensional stability  etc. The optimization method and the baffle design can be helpful to other coaxial telescopes  such as Cassegrain  Gregorian and their subdivisions. 2012 IEEE.  
Determination of optimum process parameters in gas-assisted injection molding (EI CONFERENCE) 会议论文
2011 International Conference on Electrical Information and Mechatronics, ICEIM2011, December 23, 2011 - December 25, 2011, Jiaozuo, China
Zi K.; Chen L.
收藏  |  浏览/下载:13/0  |  提交时间:2013/03/25
With finite element analysis software Moldflow  numerical simulation and studies about FM truck roof handle were conducted on gas-assisted injection molding process. The influences of melt pre-injection shot  gas pressure  delay time and melt temperature were observed by using multi-factor orthogonal experimental method. According to the analysis of the factors' impact on evaluation index  the optimized parameter combination is obtained. Therefore the optimization design of technological parameters is done. The results show that during the gas-assisted injection molding  optimum pre-injection shot is 94%  gas pressure is 15MPa  delay time is 0.5s  melt temperature is 240 C. This study provided a more practical approach for the gas-assisted injection molding process optimization.  
Efficient rate control technique for CCSDS image encoding (EI CONFERENCE) 会议论文
IEEE 2nd International Conference on Computing, Control and Industrial Engineering, CCIE 2011, August 20, 2011 - August 21, 2011, Wuhan, China
Jin L.
收藏  |  浏览/下载:87/0  |  提交时间:2013/03/25
For the limitation of data transmission bandwidth and real time transmission demand  generally image compression is required to implement the precise and flexible rate control algorithm. Rate control is an important issue in the image compression field. This paper considers the problem of rate allocation to each encoded segment for CCSDS image compression. One straightforward method is to allocate an equal amount of rate to each segment based on the average of the total number of compressed bytes. The obvious drawback of this method is that different segment will be reconstructed to different quality  so the overall quality of the reconstructed image will not be optimized. For the shortage of the original rate control method  as to improve the overall quality of the reconstructed image  an improved rate control algorithm is proposed for CCSDS image encoding. The key component of the proposed rate control method is the appropriate rate allocation. Experiments on the test images show that the PSNR can be increased at about 0.3dB on average  compared to the original algorithm. Therefore  experimental results confirm the effectiveness of the proposed algorithm in terms of objective evaluation  and the rate-distortion performance of the reconstructed image is improved. 2011 IEEE.  
The effect of backlash nonlinear on resonance frequency of electric actuator transmission system (EI CONFERENCE) 会议论文
3rd IEEE International Conference on Advanced Computer Control, ICACC 2011, January 18, 2011 - January 20, 2011, Harbin, China
Han X.; Ge M.; Bai Y.; Jia H.; Ge W.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
In order to study the effect of backlash nonlinear on resonance frequency of electric actuator transmission system  then  Finally  in the premise of meeting the stability  the dynamic equilibrium equation of transmission system with backlash is established  it makes dynamic simulation analysis for the transmission system based on virtual prototype technology  it establishes balanced equation of dynamics system with backlash  the effect of backlash on system natural frequency and resonance frequency  and the theoretical values and simulation values are compared. Theoretical analysis and simulation results show that the theoretical analysis is basically consistent with simulation results when it is zero backlash  and does some theory research and dynamic analysis of backlash nonlinearity and system natural frequency and resonance frequency. First  and the error of theoretical analysis and simulation results is within 10%. Therefore  according to describing function to theoretically model the backlash nonlinear  it can be concluded that considering the transmission system theoretical analysis of backlash nonlinearity is feasible  the relation between describing function and the amount of backlash and input amplitude is analyzed  and it is much closer to the actual system with instructive significance. 2011 IEEE.  
Design of reimaging F/1.0 long-wavelength infrared optical system (EI CONFERENCE) 会议论文
International Symposium on Photoelectronic Detection and Imaging 2011: Advances in Infrared Imaging and Applications, May 24, 2011 - May 24, 2011, Beijing, China
Zhang X.; Liu B.; Jia H.-G.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
A reimaging F/1.0 long-wavelength infrared optical system is proposed. The design has a flexible opto-mechanical layout. The design process is as follows. Firstly  the catadioptric reimaging system consists of two reflecting mirrors and a relay lenses. Two reflecting mirrors make up of the first imaging system and are therefore free of chromatic aberrations  while low dispersion lenses were used in the reimaging system  so the optical system do not need achromatic design for a high image quality. Then  to correct high-order aberrations resulting from large relative aperture  more parameters need to be used with aspheric or diffractive surfaces due to modern optic technology development. Here  aspheric is selected for easily manufacture. Finally  the design is completed with the help of ZEMAX software. The effective focal length of the objective is 120mm and the field of view (FOV) is 4. The simulated final design shows adequate image quality and the modulation transfer function (MTF) is close to diffraction limit. The effect of the surrounding environmental temperature is analyzed using the concept of thermal defocusing  and the thermal compensation is discussed. 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).  


©版权所有 ©2017 CSpace - Powered by CSpace