The Design and Analysis of Piezoresistive Shuriken-Structured Diaphragm Micro-Pressure Sensors
期刊论文
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2017
Guan, Taotao
;
Yang, Fang
;
Wang, Wei
;
Huang, Xian
;
Jiang, Boyan
;
Zhang, Dacheng
收藏
  |  
浏览/下载:5/0
  |  
提交时间:2017/12/03
High sensitivity and linearity
piezoresistive pressure sensor
shuriken-structured diaphragm
SENSITIVITY
LINEARITY
SILICON
RANGES
A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics
期刊论文
SENSORS, 2015, 卷号: 15, 页码: 27359-27373
作者:
Huang, Haiyun
;
Wang, Dejun
;
Xu, Yue
收藏
  |  
浏览/下载:4/0
  |  
提交时间:2019/12/09
monolithic Hall sensor
sensitivity and linearity
Hall offset
dynamic offset cancellation technique
A high sensitivity and high linearity pressure sensor based on a peninsula-structured diaphragm for low-pressure ranges
期刊论文
sensors and actuators a physical, 2014
Huang, Xian
;
Zhang, Dacheng
收藏
  |  
浏览/下载:8/0
  |  
提交时间:2015/11/10
MEMS pressure sensor
Peninsula-structured diaphragm
Sensitivity and linearity
FEM
Sensor fabrication
SIMULATION
SILICON
BOSS
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE)
会议论文
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
Wang Y.-L.
;
Song K.-F.
;
Zhang W.-L.
;
Li J.-L.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In the device
a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source
and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system
so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least
the sample fluorescence through the integrating sphere and come to the grating monochromator
The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device
SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process
signal-to-noise ratio(SNR) will be improved
also adjust delay time
ampling frequency and sampling number arbitrarily. By testing
the sensitivity is 10-12mol/L(substance marked by Eu3+)
examination repeat is &le2.5%
examination linearity is from 10 -8mol/L to 10-12mol/L
correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody
and solve the tumor
genetic variation
the virus protein detection. 2009 SPIE.