CORC

浏览/检索结果: 共9条,第1-9条 帮助

已选(0)清除 条数/页:   排序方式:
Efficient hyperentanglement concentration for N-particle Greenberger-Horne-Zeilinger state assisted by weak cross-Kerr nonlinearity 期刊论文
QUANTUM INFORMATION PROCESSING, 2016, 卷号: 15, 页码: 2033-2052
作者:  Liu, Huan-Juan;  Xia, Yan;  Song, Jie
收藏  |  浏览/下载:3/0  |  提交时间:2019/11/21
Teleportation of a Photonic Qubit with Non-maximally Entangled State by Using Weak Cross-Kerr Nonlinearities 期刊论文
International Journal of Theoretical Physics, 2014, 卷号: Vol.53 No.4, 页码: 1225-1232
作者:  Zhang, W;  Rui, PS;  Zhang, ZY;  Xiong, KW
收藏  |  浏览/下载:4/0  |  提交时间:2019/04/24
Effective protocol for preparation of three-atom Greenberger-Horne-Zeilinger state and W state with the help of cross-Kerr nonlinearity 期刊论文
CENTRAL EUROPEAN JOURNAL OF PHYSICS, 2013, 卷号: 11, 页码: 1030-1035
作者:  Kang, Yi-Hao;  Xia, Yan;  Lu, Pei-Min
收藏  |  浏览/下载:2/0  |  提交时间:2019/11/21
Error compensation of four and five buckets wavefront extraction algorithms in phase-shifting interferometer 期刊论文
OPTIK, 2013, 卷号: 124, 期号: 22, 页码: 5624-5627
作者:  Zhu, Mingxin;  Bai, Fuzhong;  Gan, Shiming;  Huang, Kaizheng;  Huang, Linhai
收藏  |  浏览/下载:13/0  |  提交时间:2015/04/17
Nondestructive two-photon parity detector with near unity efficiency 期刊论文
Optics Communications, 2013, 卷号: 296, 页码: 153-157
作者:  Wang, Xin-Wen*;  Tang, Shi-Qing;  Xie, Li-Jun;  Zhang, Deng-Yu
收藏  |  浏览/下载:2/0  |  提交时间:2019/12/24
Analysis of measuring errors for the visible light phase-shifting point diffraction interferometer (EI CONFERENCE) 会议论文
2010 OSA-IEEE-COS Advances in Optoelectronics and Micro/Nano-Optics, AOM 2010, December 3, 2010 - December 6, 2010, Guangzhou, China
Zhang Y.; Jin C.; Lu Z.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
In order to improve the measuring accuracy of the visible light phase-shifting point diffraction interferometer (PS/PDI) for the extreme ultraviolet lithography (EUVL) aspheric mirrors  the main measuring errors will be discussed in this paper. At first  the elementary configuration and measuring principle of the visible light phase-shifting point diffraction interferometer are introduced briefly  then the different errors which are possible to affect the measuring result are summed up  the errors include PZT phase-shifting error  detector nonlinearity error  detector quantization error  wavelength instability error and intensity instability error of the laser source  vibration error  air refractivity instability error and so on. Through detailed analysis and simulation  the magnitude of these errors can be obtained. By analysing the reasons which cause these errors and the relationship between these errors and interferometer configuration parameters  some methods are put forward to avoid or restrain these errors accordingly.  
Linearity measurement for image-intensified CCD (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Zhao Y.; Zhang L.; Yan F.; Gu Y.; Wan L.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)  technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed  and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system  and calibration of the filters' transmittance in different working positions has been done. Meanwhile  to assure the uniform of the received radiation on the target of the detector at any test points  an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization  the attenuation film with transmission  integrating sphere  optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument  the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Digital correction of wave-front errors caused by detector nonlinearity of second order in phase-shifting interferometry 期刊论文
Optics Communications: A Journal Devoted to the Rapid Publication of Short Contributions in the Field of Optics and Interaction of Light with Matter, 2004, 期号: 1, 页码: 223-228
作者:  Q. Liu;  L.Z. Cai;  M.Z. He
收藏  |  浏览/下载:2/0  |  提交时间:2020/01/03
Digital correction of wave-front errors caused by detector nonlinearity of second order in phase-shifting interferometry 期刊论文
OPTICS COMMUNICATIONS, 2004, 卷号: 239, 期号: 1-3, 页码: 223-228
作者:  Liu, Q;  Cai, LZ;  He, MZ
收藏  |  浏览/下载:5/0  |  提交时间:2020/01/03


©版权所有 ©2017 CSpace - Powered by CSpace