TiO2 nanowire arrays modified with a simultaneous "etching, doping and deposition" technique for ultrasensitive amperometric immunosensing | |
Liu Xiaoqiang[1]; Huo Xiaohe[2]; Liu Peipei[3]; Tang Yunfei[4]; Xu Jun[5]; Ju Huangxian[6] | |
刊名 | BIOSENSORS & BIOELECTRONICS |
2017 | |
卷号 | 92页码:171-178 |
关键词 | Amperometry Immunosensor MoS2 TiO2 nanowire arrays TiO2 nanorod Carcinoembryonic antigen |
ISSN号 | 0956-5663 |
DOI | http://dx.doi.org/10.1016/j.bios.2017.02.019 |
URL标识 | 查看原文 |
收录类别 | SCI(E) ; EI ; PUBMED |
WOS记录号 | WOS:000396946600025 |
内容类型 | 期刊论文 |
URI标识 | http://www.corc.org.cn/handle/1471x/5188289 |
专题 | 河南大学 |
作者单位 | 1.[1]Institute of Environmental and Analytical Sciences, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan Province 475004, PR China. Electronic address: 13781157777@163.com. 2.[2]Institute of Environmental and Analytical Sciences, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan Province 475004, PR China. 3.[3]Institute of Environmental and Analytical Sciences, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan Province 475004, PR China. 4.[4]Institute of Environmental and Analytical Sciences, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan Province 475004, PR China. 5.[5]Institute of Environmental and Analytical Sciences, College of Chemistry and Chemical Engineering, Henan University, Kaifeng, Henan Province 475004, PR China. 6.[6]State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210023, PR China. Electronic address: hxju@nju.edu.cn. |
推荐引用方式 GB/T 7714 | Liu Xiaoqiang[1],Huo Xiaohe[2],Liu Peipei[3],et al. TiO2 nanowire arrays modified with a simultaneous "etching, doping and deposition" technique for ultrasensitive amperometric immunosensing[J]. BIOSENSORS & BIOELECTRONICS,2017,92:171-178. |
APA | Liu Xiaoqiang[1],Huo Xiaohe[2],Liu Peipei[3],Tang Yunfei[4],Xu Jun[5],&Ju Huangxian[6].(2017).TiO2 nanowire arrays modified with a simultaneous "etching, doping and deposition" technique for ultrasensitive amperometric immunosensing.BIOSENSORS & BIOELECTRONICS,92,171-178. |
MLA | Liu Xiaoqiang[1],et al."TiO2 nanowire arrays modified with a simultaneous "etching, doping and deposition" technique for ultrasensitive amperometric immunosensing".BIOSENSORS & BIOELECTRONICS 92(2017):171-178. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论