×
验证码:
换一张
忘记密码?
记住我
CORC
首页
科研机构
检索
知识图谱
申请加入
托管服务
登录
注册
在结果中检索
科研机构
长春光学精密机械与... [24]
内容类型
会议论文 [24]
发表日期
2014 [1]
2012 [2]
2010 [7]
2009 [3]
2008 [1]
2007 [2]
更多...
×
知识图谱
CORC
开始提交
已提交作品
待认领作品
已认领作品
未提交全文
收藏管理
QQ客服
官方微博
反馈留言
浏览/检索结果:
共24条,第1-10条
帮助
限定条件
内容类型:会议论文
专题:长春光学精密机械与物理研究所
第一署名单位
第一作者单位
通讯作者单位
已选(
0
)
清除
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
Phase retrieval using regularization method in intensity correlation imaging
会议论文
International Symposium on Optoelectronic Technology and Application 2014: Imaging Spectroscopy; and Telescopes and Large Optics, IPTA 2014, May 13, 2014 - May 15, 2014, Beijing, China
Li X.
;
Gao X.
;
Tang J.
;
Lu C.
;
Wang J.
;
Wang B.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2015/04/27
Reagentless near-infrared determination of cholesterol in undiluted human serum using interval partial least square (EI CONFERENCE)
会议论文
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Gao H.
;
Lu Q.
;
Huang F.
收藏
  |  
浏览/下载:22/0
  |  
提交时间:2013/03/25
In order to determination of cholesterol in human serum with no reagent using nearinfrared (NIR) spectroscopy. Interval partial least square (iPLS) was proposed as an effective variable selection approach for multivariate calibration. For this purpose
an independent sample set was employed to evaluate the prediction ability of the resulting model. The spectrum was split into different interval. Then
the informative region of cholesterol (1688-1760nm)
in which the PLS model has a low RMSEP with 0.241mmol/L and a high R with 0.975
is selected with 23 intervals. The results indicate that
the informative region of cholesterol can be obtained by iPLS and applied to design the simpler reagentless NIR instruments for inexpensive cholesterol measurement in future. (2012) Trans Tech Publications
Switzerland.
Correction of baseline drifts due to the pressure changes between attenuated total reflection prism and human skin for noninvasive blood glucose sensing with Fourier Transform infrared spectroscopy (EI CONFERENCE)
会议论文
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Wang D.
;
Lu Q.
;
Yao L.
收藏
  |  
浏览/下载:42/0
  |  
提交时间:2013/03/25
For noninvasive blood sensing with attenuated total reflection (ATR)-Fourier Transform infrared spectroscopy(FTIR)
the baseline of spectra human skin will drift because of the exitence of pressure changes between ATR prism and human skin. To correct the baseline drifts
In the paper
the fingertips spectra in mid-infrared were recorded under the special conditions. A line equation was calculated using the last 14 spectra coupled with the linear regression analysis between the absorbance spectra at the 1035cm-1 and the 950cm-1. And the corrected absorption intensities
after the removal of the baseline drifts
can be applied for the quantification of glucose concentrations in blood easily with the given method in the paper. (2012) Trans Tech Publications
Switzerland.
Design of compound Fresnel-R lenses for new high-efficient photovoltaic concentrator (EI CONFERENCE)
会议论文
Nonimaging Optics: Efficient Design for Illumination and Solar Concentration VII, August 1, 2010 - August 4, 2010, San Diego, CA, United states
Jing L.
;
Liu H.
;
Lu Z.
;
Zhao H.
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2013/03/25
A new design of compound Fresnel-R concentrator is presented which is composed of two lenses: a primary lens (Fresnel lens) that works by total internal reflection at outer facets but refraction at inner facets
and a secondary lens that works by refraction. In contrast to previous Fresnel lens concentrator
this design increases the acceptance angle
improves the irradiance uniformity on the solar cell
and reduces the aspect ratio significantly. Another outstanding advantage of this concentrator is the fact that it mainly works by performing total internal reflection
reducing chromatic dependence as well as Fresnel losses. An optical efficiency more than 80% can be achieved. Moreover
in order to reduce the influence of manufacture accuracy and to increase the optical efficiency further
the central part of the bottom of the secondary lens which directly adhered to the solar cell is designed as a cone-shaped prism to collect the sunlight that doesn't reach the solar cell. 2010 SPIE.
Sort optimization algorithm of median filtering based on FPGA (EI CONFERENCE)
会议论文
2010 International Conference on Machine Vision and Human-Machine Interface, MVHI 2010, April 24, 2010 - April 25, 2010, Kaifeng, China
Lu Y.
;
Jiang L.
;
Dai M.
;
Li S.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
The traditional sorting algorithm of median filtering is optimized according to the hardware structure features of FPGA. FPGA is used to acquire the data parallelly for comparing the data of the same column in the median filtering window. Comparing results shared by adjacent filter window are saved temporarily to match the new round of median filtering by using FPGA internal resources. This method can reduce the comparing times from current 21 down to 13
and improve the algorithm efficiency nearly 40%.The experimental results prove that the optimized algorithm can filter a 1K1K gray-level image in about 20ms
which ensure the proposed algorithm can be applied in the real-time image median filtering system. 2010 IEEE.
Research on the laboratory radiometric calibration of the thermal imager (EI CONFERENCE)
会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Lu Z.
;
Sun Q.
;
Wang J.
;
Lu Z.
;
Liu Y.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
The radiometric calibration of the thermal imager was investigated to build the relationship between the input radiance and the digital output to realize the temperature measurement. The radiometric calibration was implemented in the State Key Laboratory of Applied Optics. A standard black body source was served as radiation source. The response of the thermal imager to the input radiance was tested for different gains. The experimental results show that the average grey level of the output imaging is linear dependence of the input radiance. Because the radiance in the receiving wave range of the thermal imager is linear with the black body's temperature based on Planck's law of radiation
the average grey level of the output image is also linear with the black body's temperature after fitting a curve to the experiment data points. Then the relationship of the response and the gain was studied when the black body's temperature kept constant. The preliminary analysis of calibration data shows that the response of the thermal imager is linear and the average grey value of the image is directly proportion to the gain. According to the experimental results
the reference gains and the dynamic range of temperature measurement were obtained. Finally
the uncertainty influencing the calibration results was analyzed
the analysis shows the maximal uncertainty is 5.2%
which can meet the calibration requirement less than 10%. 2010 Copyright SPIE - The International Society for Optical Engineering.
Analysis of measuring errors for the visible light phase-shifting point diffraction interferometer (EI CONFERENCE)
会议论文
2010 OSA-IEEE-COS Advances in Optoelectronics and Micro/Nano-Optics, AOM 2010, December 3, 2010 - December 6, 2010, Guangzhou, China
Zhang Y.
;
Jin C.
;
Lu Z.
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2013/03/25
In order to improve the measuring accuracy of the visible light phase-shifting point diffraction interferometer (PS/PDI) for the extreme ultraviolet lithography (EUVL) aspheric mirrors
the main measuring errors will be discussed in this paper. At first
the elementary configuration and measuring principle of the visible light phase-shifting point diffraction interferometer are introduced briefly
then the different errors which are possible to affect the measuring result are summed up
the errors include PZT phase-shifting error
detector nonlinearity error
detector quantization error
wavelength instability error and intensity instability error of the laser source
vibration error
air refractivity instability error and so on. Through detailed analysis and simulation
the magnitude of these errors can be obtained. By analysing the reasons which cause these errors and the relationship between these errors and interferometer configuration parameters
some methods are put forward to avoid or restrain these errors accordingly.
White-light spectral scanning interferometry for surface measurement system (EI CONFERENCE)
会议论文
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Wang C.
;
Cao N.
;
Lu J.
;
Guan J.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
The paper introduces the white-light spectral scanning interferometry for surface measurement. This interferometry can be used to measure the roughness of both smooth surfaces and those with large step heights. This real-time surface measurement can be achieved using acousto-optic tuneable filtering (AOTF) technique without mechanical scanning. At first
the structure and principle of this interferometry is introduced. Then the algorithm of the surface roughness measurement is proposed. What's more
the experiment with standard test piece is conducted. Compared with the traditional laser-light interferometry
the data shows that the proposed method has a higher accuracy which is proved to be nano-scale. A conclusion is given at last in which the superiorities and the limitations of the proposed system were discussed. 2010 SPIE.
Direct adaptive fuzzy decentralized control for reconfigurable modular manipulators (EI CONFERENCE)
会议论文
29th Chinese Control Conference, CCC'10, July 29, 2010 - July 31, 2010, Beijing, China
Zhu M.
;
Lu P.
;
Zhu L.
;
Li Y.
收藏
  |  
浏览/下载:27/0
  |  
提交时间:2013/03/25
A stable direct adaptive fuzzy decentralized control for reconfigurable modular manipulators is proposed to satisfy the concept of modular software. For the development of the decentralized control
the dynamics of reconfigurable manipulators is represented as a set of interconnected subsystems. The fuzzy logic systems are introduced to model the unknown dynamics of subsystem and the interconnection term by using adaptive algorithm. Based on Lyapunov stability theorem
the stability of the closed-loop systems can be verified. The simulation results are presented to show the effectiveness of the proposed adaptive fuzzy decentralized control schemes.
Development and radiance calibration of three-waveband camera (EI CONFERENCE)
会议论文
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
Lu Z.
;
Sun Q.
;
Wang J.
;
Lu Z.
;
Liu Y.
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path
the required waveband was selected. The optical system which can image in ultraviolet
visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost
small size and light in weight. To obtain a high imaging quality
the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments
the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet
0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.
©版权所有 ©2017 CSpace - Powered by
CSpace