CORC

浏览/检索结果: 共4条,第1-4条 帮助

已选(0)清除 条数/页:   排序方式:
Method of auto multi-exposure for high dynamic range imaging (EI CONFERENCE) 会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Piao Y.; Xu W.
收藏  |  浏览/下载:13/0  |  提交时间:2013/03/25
This paper proposes a method for calculating the multi-exposure times fast and accurately when the scene has a high dynamic range  minimizing the pictures needed to take and improving the dynamic range of the CCD system. The proposed method first measures the camera's response function referring [10]. After that the median value of the output picture is adjusted to be in the middle range of the system output by changing the exposure time. It can be inferred from the histogram of the current picture whether it's a high dynamic range scene by calculating the number of pixels under exposed and over exposed. Once again the under and over exposed pixels are adjusted to be in the middle according to the camera's response function. Finally different exposed pictures (2 or 3) are fused together by Gaussian function and the dynamic range is compressed by y correction. Experimental results on UNIQ-UM400 analog camera and a digital acquisition system show that the algorithm works well and solve the problem of low dynamic range of CCD camera. 2010 IEEE.  
Study on dynamic imaging on TDI CCD optical remote sensor of push-broom technology (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Gao M.-H.; Zhao G.-J.; Liu L.; Ren J.-Y.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
A set special detecting system is proposed based on TDICCD push-broom technology applying in dynamic imaging detecting experiment of space optics remote sensor. In the system  In the course of detecting  push-broom movement of the satellite is simulated through using double supporting U structure precision rotary platform with remote sensor by angular speed 0.555/s  regard Nyquist frequency target as detecting aim  within the range of 5 and control precision on steady speed achieves 0.3%  in order to solve matching uncertainty between the CCD pixel and the vertical target strip image when the remote sensor does push-broom  make matching simplify  enhance the measurement result the accuracy. So the tolerance a/n arithmetic progression gap target strip is joined in each group of rectangular vertical group target strip. The remote sensor obtains in vertical  the level and 45 the direction 0 fields of view  0.86 the field of view Nyquist frequency target strip image after detected  a group target strip which can precision matching to TDICCD pixel at least can be obtained through analysis and dealing with 0.86 field of view's target strip image. The experiment not only verifies the detecting system's feasibility but simultaneously verifies whether to have the high quality dynamic imaging quality when TDICCD push-broom technology is adopted on the remote sensor developed. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Development and radiance calibration of three-waveband camera (EI CONFERENCE) 会议论文
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
Lu Z.; Sun Q.; Wang J.; Lu Z.; Liu Y.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
An imaging system with three-waveband sharing one lens and an area CCD was developed. By rotating different filters into the beam path  the required waveband was selected. The optical system which can image in ultraviolet  visible and near infrared region was designed and the signal collecting system was integrated. The optical design and system integration have some advantages such as low cost  small size and light in weight. To obtain a high imaging quality  the radiation calibration is carried out in order to establish the relation between the average grey level of output image and the input radiance from the integrating sphere. According to the calibration data in experiments  the radiation dynamic range and the best working point of the system are determined. The experiment result shows that the dynamic range of the image system is maximal when the exposure time is 8ms in ultraviolet  0.5ms in visible and 0.125ms in near infrared region. 2010 IEEE.  
Research on method of measuring the time of remote explosion point (EI CONFERENCE) 会议论文
27th International Congress on High-Speed Photography and Photonics, September 17, 2006 - September 22, 2006, Xi'an, China
Zhou J.; Yin H.; Xu K.; Fu Y.
收藏  |  浏览/下载:14/0  |  提交时间:2013/03/25


©版权所有 ©2017 CSpace - Powered by CSpace