×
验证码:
换一张
忘记密码?
记住我
CORC
首页
科研机构
检索
知识图谱
申请加入
托管服务
登录
注册
在结果中检索
科研机构
长春光学精密机械与物... [3]
内容类型
会议论文 [3]
发表日期
2009 [3]
×
知识图谱
CORC
开始提交
已提交作品
待认领作品
已认领作品
未提交全文
收藏管理
QQ客服
官方微博
反馈留言
浏览/检索结果:
共3条,第1-3条
帮助
限定条件
发表日期:2009
已选(
0
)
清除
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
Modeling and analysis of dialyte-lens auto-focusing technology for theodolite (EI CONFERENCE)
会议论文
2008 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Applications, November 16, 2008 - November 19, 2008, Beijing, China
Wu L.-T.
;
Qiao Y.-F.
;
Wu D.-K.
;
Cai S.
收藏
  |  
浏览/下载:14/0
  |  
提交时间:2013/03/25
In order to realize real-time auto-focusing for theodolite
lens-apart method was designed with the corresponding math model built and analyzed. An Object beam splitted after the first image surface of the theodolite traveled through two dialyte lens and then was imaged on CCD. The distance between two spots when exactly focused was set as the calibration value
and the relationship between defocus distance and spot offset was given. The influence of tracking center shift and divergence angle etc. on focusing accuracy was analyzed. Compared with the traditional focusing method
this scheme has a higher accuracy
faster calculation
higher tolerance for environment temperature and a simpler construction. The experiment result exhibited a resolution higher than 0.056mm
which shows a bright engineering application prospect for this method. 2009 SPIE.
Estimation algorithm of mobile OFDM CFOs based on step-size (EI CONFERENCE)
会议论文
2009 International Conference on Information Engineering and Computer Science, ICIECS 2009, December 19, 2009 - December 20, 2009, Wuhan, China
Lin L.
;
Qiao Y.-F.
;
Su W.-X.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
In order to maintain orthogonality among subcarriers for mobile OFDM
a CFOs step-size estimation model is established to avoid severe performance degradation caused by ICI
and algorithmic stability
step-size parameter
the error of CFOs estimate and etc are investigated. First
after an averaging window algorithm is introduced
the mathematic model of step-size estimation algorithm is obtained through step-size parameter and time-varying CFOs. Then
based on the results of MATLAB simulation
the determination of step-size parameter
the advantages of step-size algorithm and precision are discussed. Finally
time sequence plots of added CP
interleaver and subcarrier modulation with VHDL are presented. Experimental results indicate that the maximum of CFOs errors is 0.00987 in 3 variance interval
when mobile velocity is 400 km/h
according with verdicted principle that in order for the ICI effects to be negligible
the error of CFOs estimation must be accurate within 1-2% of the subcarrier spacing
and programs can correctly implement on circuit board. 2009 IEEE.
A sensitive solid-phase time-resolved fluorescence immunoassay apparatus (EI CONFERENCE)
会议论文
International Symposium on Photoelectronic Detection and Imaging 2009: Laser Sensing and Imaging, June 17, 2009 - June 19, 2009, Beijing, China
Wang Y.-L.
;
Song K.-F.
;
Zhang W.-L.
;
Li J.-L.
收藏
  |  
浏览/下载:25/0
  |  
提交时间:2013/03/25
In the device
a He-Ne laser of flash frequency 1-20 Hz was adopted as exciting light source
and three key technical problems have been solved successfully in order to enhance the detecting sensitivity and measuring stability of the device for time-resolved fluorimmunoassays(TRFIA) [1]. The first one is to design optimum exciting optical system
so that the exciting light beam excite the sample most effectively. The second one is to have a project spectrum filter which can reduce the affection of the background light to the photomultiplier tube and also ensure influence of the stray light and mixed diffusion light to the sample fluorescence to the least
the sample fluorescence through the integrating sphere and come to the grating monochromator
The right wavelength will be chosed through changing the angle of incidence of the grating monochromator. The third one is to simulate the principle of sample averaging of BOXCAR averager. In the device
SCM was used as primary controller and CPLD was used as timing controller. Through the preparation process
signal-to-noise ratio(SNR) will be improved
also adjust delay time
ampling frequency and sampling number arbitrarily. By testing
the sensitivity is 10-12mol/L(substance marked by Eu3+)
examination repeat is &le2.5%
examination linearity is from 10 -8mol/L to 10-12mol/L
correlation coefficient is 99.98%(p&le0.01). The instrument is advanced for ultrasensitive detection of antigen and antibody
and solve the tumor
genetic variation
the virus protein detection. 2009 SPIE.
©版权所有 ©2017 CSpace - Powered by
CSpace