The exergy and energy level analysis of a combined cooling, heating and power system driven by a small scale gas turbine at off design condition | |
Chen, Qiang1,2; Han, Wei1; Zheng, Jian-jiao1; Sui, Jun1; Jin, Hong-guang1 | |
刊名 | APPLIED THERMAL ENGINEERING |
2014-05-01 | |
卷号 | 66期号:1-2页码:590-602 |
关键词 | CCHP system Off-design performance Energy level analysis Exergy Distributed energy system |
英文摘要 | This paper presents the off design performance analysis of a combined cooling, heating, and power (CCHP) system consisting of a small-scale gas turbine, an exhaust-fired double-effect absorption chiller, and a heat exchanger. The energy and exergy analyses of the CCHP system are investigated under the rated and part-load conditions. Energy level analysis is implemented on the energy conversion processes to reveal the mechanisms of the deterioration of the CCHP performance under part-load conditions. The results show that the CCHP system is energy saving when the power output of the gas turbine exceeds 30% of the full load. It is also found that the CO2 emission of the CCHP system reduced by 66.7%-70.5%, compared with conventional separation system, when the power output of gas turbine increased from about 30% to 100%. Energy level results reveal that the combustor of the small-scale gas turbine mainly contributed to the deteriorated performance of the CCHP system. In addition, a case study is carried out to illustrate the advantage of using dynamic data in the performance assessment. The case results indicate that using off-design data leads to a more realistic evaluation of the CCHP system. (C) 2014 Elsevier Ltd. All rights reserved. |
WOS标题词 | Science & Technology ; Physical Sciences ; Technology |
类目[WOS] | Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics |
研究领域[WOS] | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
关键词[WOS] | TRIGENERATION SYSTEM ; EVOLUTIONARY ALGORITHM ; PERFORMANCE ANALYSIS ; CCHP SYSTEM ; OPTIMIZATION ; COGENERATION ; TECHNOLOGIES ; GENERATION ; EMISSIONS ; OPERATION |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000336352000061 |
公开日期 | 2015-12-22 |
内容类型 | 期刊论文 |
源URL | [http://ir.etp.ac.cn/handle/311046/105961] |
专题 | 工程热物理研究所_中国科学院工程热物理所(论文库)_期刊论文(SCI) |
作者单位 | 1.Chinese Acad Sci, Inst Engn Thermophys, Beijing, Peoples R China 2.Univ Chinese Acad Sci, Beijing, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Qiang,Han, Wei,Zheng, Jian-jiao,et al. The exergy and energy level analysis of a combined cooling, heating and power system driven by a small scale gas turbine at off design condition[J]. APPLIED THERMAL ENGINEERING,2014,66(1-2):590-602. |
APA | Chen, Qiang,Han, Wei,Zheng, Jian-jiao,Sui, Jun,&Jin, Hong-guang.(2014).The exergy and energy level analysis of a combined cooling, heating and power system driven by a small scale gas turbine at off design condition.APPLIED THERMAL ENGINEERING,66(1-2),590-602. |
MLA | Chen, Qiang,et al."The exergy and energy level analysis of a combined cooling, heating and power system driven by a small scale gas turbine at off design condition".APPLIED THERMAL ENGINEERING 66.1-2(2014):590-602. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论