Preparation of phenyl-silica hybrid monolithic column with "one-pot" process for capillary liquid chromatography
Zhang, Zhenbin1,2; Lin, Hui1,2; Ou, Junjie1; Qin, Hongqiang1,2; Wu, Ren'an1; Dong, Jing1; Zou, Hanfa1
刊名journal of chromatography a
2012-03-09
卷号1228页码:263-269
关键词One-pot Sol-gel Phenyl-silica hybrid monolith Capillary liquid chromatography
英文摘要a phenyl-silica hybrid monolithic column for capillary liquid chromatography (clc) was prepared through "one-pot" process by con-currently using benzyl methacrylate and alkoxysilanes. the effects of the molar ratio of tetramethoxysilane/vinyltrimethoxysilane (tmos/vtms), polycondensation temperature, content of supramolecule template (cetyltrimethylammonium bromide, ctab), ratio of n,n'-dimethylformamide/methanol (v/v), the volume of benzyl methacrylate on the morphologies of the prepared phenyl-silica hybrid monolithic columns were investigated in detail. the permeability of the hybrid monolithic column was calculated as 3.23 x 10(-13) m(2), and the minimum plate height was determined as 8.38 mu m which corresponding to 119,000 theoretical plates per meter. separation of various neutral, polar and basic analytes as well as small peptides on the hybrid monolithic column was achieved by clc and showed high efficiency and satisfactory reproducibility. moreover, the prepared hybrid monolithic column was also applied for the analysis of cryptic digests of bovine serum albumin (bsa), ovalbumin, a-casein, cytochrome c and myoglobin by clc tandem mass spectrometry (clc-ms/ms), and the results showed that the separation performance was close to that of the octadecylsilane (c18) packed capillary column which demonstrating its potential in proteome analysis. moreover, since the prepolymerization system was mainly consisted of organic solvents (methanol and n,n'-dimethylformamide). various hydrophobic monomers could be potentially used to prepare organic-silica hybrid monolithic columns through "one-pot" approach. (c) 2011 elsevier b.v. all rights reserved.
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]ionization mass-spectrometry ; stationary phases ; proteome analysis ; inner diameters ; separation ; electrochromatography ; efficiency ; single
收录类别SCI
语种英语
WOS记录号WOS:000301406100026
公开日期2015-11-17
内容类型期刊论文
源URL[http://159.226.238.44/handle/321008/142911]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
2.Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Zhenbin,Lin, Hui,Ou, Junjie,et al. Preparation of phenyl-silica hybrid monolithic column with "one-pot" process for capillary liquid chromatography[J]. journal of chromatography a,2012,1228:263-269.
APA Zhang, Zhenbin.,Lin, Hui.,Ou, Junjie.,Qin, Hongqiang.,Wu, Ren'an.,...&Zou, Hanfa.(2012).Preparation of phenyl-silica hybrid monolithic column with "one-pot" process for capillary liquid chromatography.journal of chromatography a,1228,263-269.
MLA Zhang, Zhenbin,et al."Preparation of phenyl-silica hybrid monolithic column with "one-pot" process for capillary liquid chromatography".journal of chromatography a 1228(2012):263-269.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace