Enhancement in sample preconcentration by the on-line incorporation of cloud point extraction to flow injection analysis inside the chemiluminescence cell and the determination of total serum bilirubin
Lu, Chao ; Song, Guanqun ; Lin, Jin-Ming ; Huie, Carmen W.
刊名ANALYTICA CHIMICA ACTA
2007-05-08
卷号590期号:2页码:159-165
关键词on-line cloud point extraction chemiluminescence inside the collection column flow injection analysis total bilirubin human serum
英文摘要The on-line incorporation of cloud point extraction (CPE) to flow injection analysis (FIA) was previously based on the use of a cotton-packed column to entrap the analyte-containing surfactant aggregates after salt-induced CPE, and then the preconcentrated analyte was eluted into a separate detection cell for subsequent chemiluminescence (CL) detection (via the peroxyoxalate CL reaction). In the work, the on-line CPE/FIA technique was improved by the following: (1) sample preconcentration and CL detection were both carried out directly inside the collection column, thus avoiding the decrease in detection sensitivity due to sample dispersion and dilution, and (2) CL detection was performed through the reaction between nitrite and hydrogen peroxide, which is compatible with aqueous samples and should allow for chemical excitation to occur more efficiently inside the collection column. In addition to more effective sample preconcentration, the CL detection of the entrapped analytes directly inside the collection column, i.e., a unique heterogeneous microenvironment in which analyte-containing surfactant aggregates were embedded within the densely packed filtering material, may also contribute to the overall increase in CL intensity (e.g., a CL enhancement factor of ca. 1000). Under optimum experimental conditions, the calibration curve was found to be linear for the CL detection of bilirubin (5 to 120 mu g L-1), the limit of detection (S/N = 3) was 1.8 mu gL(-1), and the R.S.D. was ca. 2.6% (n = 30) for 20 mu g L-1 bilirubin. Good agreements were obtained for the determination of total bilirubin in certified reference human serum samples between the present approach and an established clinical method. (c) 2007 Published by Elsevier B.V.
WOS记录号WOS:000246321300004
内容类型期刊论文
源URL[http://ir.rcees.ac.cn/handle/311016/22455]  
专题生态环境研究中心_环境化学与生态毒理学国家重点实验室
推荐引用方式
GB/T 7714
Lu, Chao,Song, Guanqun,Lin, Jin-Ming,et al. Enhancement in sample preconcentration by the on-line incorporation of cloud point extraction to flow injection analysis inside the chemiluminescence cell and the determination of total serum bilirubin[J]. ANALYTICA CHIMICA ACTA,2007,590(2):159-165.
APA Lu, Chao,Song, Guanqun,Lin, Jin-Ming,&Huie, Carmen W..(2007).Enhancement in sample preconcentration by the on-line incorporation of cloud point extraction to flow injection analysis inside the chemiluminescence cell and the determination of total serum bilirubin.ANALYTICA CHIMICA ACTA,590(2),159-165.
MLA Lu, Chao,et al."Enhancement in sample preconcentration by the on-line incorporation of cloud point extraction to flow injection analysis inside the chemiluminescence cell and the determination of total serum bilirubin".ANALYTICA CHIMICA ACTA 590.2(2007):159-165.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace