Mapping of bioluminescent images onto CT volume surface for dual-modality BLT and CT imaging
Chen, Xueli1,2; Liang, Jimin1; Qu, Xiaochao1; Hou, Yanbin1; Zhu, Shouping1; Chen, Duofang1; Gao, Xinbo2; Tian, Jie1,3
刊名JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY
2012
卷号20期号:1页码:31-44
关键词Dual-modality imaging bioluminescence tomography (BLT) computed tomography (CT) spatial registration light flux recovering
英文摘要We present a method for mapping the two-dimensional (2D) bioluminescent images (BLIs) onto a three-dimensional (3D) body surface derived from the computed tomography (CT) volume data. This mapping includes two closely-related steps, the spatial registration of the 2D BLIs into the coordinate system of the CT volume data and the light flux recovering on the body surface from BLIs. By labeling markers on the body surface, we proposed an effective registration method to achieve the spatial position alignment. The subsequent light flux recovering is presented based on the inverse process of the free-space light transport model and taking the influence of the camera lens diaphragm into account. Incorporating the mapping procedure into the bioluminescence tomography (BLT) reconstruction, we developed a dual-modality BLT and CT imaging framework to provide both optical and anatomical information. The accuracy of the registration and the light flux recovering methods were evaluated via physical phantom experiments. The registration method was found to have a mean error of 0.41 mm and 0.35 mm in horizontal and vertical direction, and the accuracy of the light flux recovering method was below 5%. Furthermore, we evaluated the performance of the dual-modality BLT/CT imaging framework using a mouse phantom. Preliminary results revealed the potential and feasibility of the dual-modality imaging framework.
WOS标题词Science & Technology ; Technology ; Physical Sciences
类目[WOS]Instruments & Instrumentation ; Optics ; Physics, Applied
研究领域[WOS]Instruments & Instrumentation ; Optics ; Physics
关键词[WOS]TOMOGRAPHY ; RECONSTRUCTION ; MOUSE ; SIMULATION
收录类别SCI
语种英语
WOS记录号WOS:000301363700004
内容类型期刊论文
源URL[http://ir.ia.ac.cn/handle/173211/4081]  
专题自动化研究所_中国科学院分子影像重点实验室
作者单位1.Xidian Univ, Sch Life Sci & Technol, Xian 710126, Shaanxi, Peoples R China
2.Xidian Univ, Sch Elect Engn, Xian 710126, Shaanxi, Peoples R China
3.Chinese Acad Sci, Inst Automat, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Chen, Xueli,Liang, Jimin,Qu, Xiaochao,et al. Mapping of bioluminescent images onto CT volume surface for dual-modality BLT and CT imaging[J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY,2012,20(1):31-44.
APA Chen, Xueli.,Liang, Jimin.,Qu, Xiaochao.,Hou, Yanbin.,Zhu, Shouping.,...&Tian, Jie.(2012).Mapping of bioluminescent images onto CT volume surface for dual-modality BLT and CT imaging.JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY,20(1),31-44.
MLA Chen, Xueli,et al."Mapping of bioluminescent images onto CT volume surface for dual-modality BLT and CT imaging".JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 20.1(2012):31-44.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace