Ultrasensitive electrochemical DNA sensor based on the target induced structural switching and surface-initiated enzymatic polymerization
Wan, Y ; Wang, PJ ; Su, Y ; Zhu, XH ; Yang, SL ; Lu, JX ; Gao, JM ; Fan, CH ; Huang, Q
刊名BIOSENSORS & BIOELECTRONICS
2014
卷号55页码:231—236
关键词SEQUENCE-SPECIFIC DETECTION STRAND-DISPLACEMENT AMPLIFICATION CHRONOCOULOMETRIC DNA SIGNAL AMPLIFICATION POLYMERASE REACTION FEMTOMOLAR DNA STEM-LOOP HYBRIDIZATION REAGENTLESS BIOSENSORS
ISSN号0956-5663
通讯作者suyan@njust.edu.cn ; zhuxinhua@mail.njust.edu.cn ; yshulin@mail.njust.edu.cn
英文摘要In this work, two electrochemical DNA sensors was developed based on the target induced structural switching of stem-loop probe (SLP) and surface initiated enzymatic polymerization (SIEP). Both of the electrochemical DNA sensors employed SLPs with the same sequence. However, one had a thiol label at its 3' terminal (the probe was named 3-SLP and the sensor was named 3-SLP-SENS) and the other at its 5' terminal (the probe was named 5-SLP and the sensor was named 5-SLP-SENS). In the initial state of the sensors, both of the probes adopted the stem-loop structure, which shielded the unlabeled terminals of capture probes from being approached. When the loop regions of the capture probes hybridized with the target DNA the conformation of the SLPs was changed to a rigid double-strand, as a result, the 5-SLP released a 3'-OH terminal for SIEP which could be catalyzed by terminal deoxynudeolidyl transferase (TdT). And the 3-SLP released a 5' phosphate terminal which is not suit for SIEP. Thus a signal probe was employed to hybridize with the 5 terminal of 3-SLP and provide a 3'-OH. Both of the sensors were then submitted to the TdT-mediated SIEP. By using biotinylated 2'-deoxyadenosine 5'-triphosphate (biotin-dATP), biotin labels are incorporated into the SIEP-generated long single-stranded DNA. Then avidin-horseradish peroxidases (Av-HRPs) were employed for specific binding to the biotin labels to produce electrochemical signals. The detection performances of two electrochemical DNA sensors were investigated and compared. It was demonstrated that though the 3-SLP-SENS employed extra signal probes, the background current was lower leading to a better detection limit By taking advantage of SLP and SIEP, this 3-SLP-SENS has been able to detect as low as 0:1 pM DNA targets with excellent differentiation ability for even single mismatches. (c) 2013 Published by Elsevier B.V. All rights reserved.
收录类别SCI
语种英语
WOS记录号WOS:000332426100036
公开日期2015-03-13
内容类型期刊论文
源URL[http://ir.sinap.ac.cn/handle/331007/14538]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Wan, Y,Wang, PJ,Su, Y,et al. Ultrasensitive electrochemical DNA sensor based on the target induced structural switching and surface-initiated enzymatic polymerization[J]. BIOSENSORS & BIOELECTRONICS,2014,55:231—236.
APA Wan, Y.,Wang, PJ.,Su, Y.,Zhu, XH.,Yang, SL.,...&Huang, Q.(2014).Ultrasensitive electrochemical DNA sensor based on the target induced structural switching and surface-initiated enzymatic polymerization.BIOSENSORS & BIOELECTRONICS,55,231—236.
MLA Wan, Y,et al."Ultrasensitive electrochemical DNA sensor based on the target induced structural switching and surface-initiated enzymatic polymerization".BIOSENSORS & BIOELECTRONICS 55(2014):231—236.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace