中文摘要星载微波辐射计采用平方律检波,物体的辐射功率与接收机的输出电压成线性关系.因此星载微波辐射计采用高低温两点定标.其中高温定标源采用处在环境温度下的黑体,低温定标源为冷空背景辐射.由Rayleigh-Jeans公式计算的物体的辐射功率与其物理温度成线性关系,但是随着物体频率的升高,Rayleigh-Jeans公式与Planck定律的近似误差越来越大,此时应根据Planck定律计算物体的辐射功率.从Planck定律出发,对毫米波,亚毫米波辐射计的定标方程进行了推导,并给出了高低温定标源的辐射功率在毫米波和亚毫米波段的表达式.
英文摘要Microwave spaceborne radiometer adopts sqare-law detection , so t he radiation of t he object received is linear to the outp ut voltage of the radiometer .Therefore ,the calibration of microwave spaceborne radiometer is performed by measuring the radiometer response to hot and cold references during operation.The hot reference is usually a blackbody under environmental temperat ure ,and the cold reference is Cosmic Background Radiation. According to Rayleigh-Jeans law ,the emission of the object is directly linear to it s absolute temperat ure.As the frequency of object increases , Rayleigh-J eans Law deviates f rom Planck's Blackbody Radiation Law ,and the radiation of object received should be calculated according to Planck's Blackbody Radiation Law.The calibration equations of millimeter and submillimeter radiometer are derived from he Planck's Law ,and t he formulas of the calibration references radiation are presented in millimeter and submillimeter bands.
学科主题微波遥感
收录类别CSCD
语种中文
CSCD记录号CSCD:3468183
内容类型期刊论文
源URL[http://ir.cssar.ac.cn/handle/122/1995]  
专题国家空间科学中心_微波遥感部
推荐引用方式
GB/T 7714
赵瑾,张德海. 星载毫米波亚毫米波辐射计定标的初步研究[J]. 遥感技术与应用,2008,23(6):717-720.
APA 赵瑾,&张德海.(2008).星载毫米波亚毫米波辐射计定标的初步研究.遥感技术与应用,23(6),717-720.
MLA 赵瑾,et al."星载毫米波亚毫米波辐射计定标的初步研究".遥感技术与应用 23.6(2008):717-720.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace