The analysis of affections to the cold space calibration source of ChangE-1 payload Microwave Detector | |
Zhang, H. Y. ; Zhang, X. H. ; Yang, J. L. | |
刊名 | Advances in Space Research |
2008 | |
卷号 | 42期号:2页码:350-357 |
关键词 | CE-1 Microwave Detector Cold space Calibration Solar radiation |
ISSN号 | 0273-1177 |
通讯作者 | 北京8701信箱 |
英文摘要 | ChangE-1 (CE-1) will be the first satellite of China in lunar orbit. Its Microwave Detector makes real-time and periodical calibration at high and low temperature points. The low brightness temperature calibration source will be provided by calibration antenna which is pointing towards the cold space.This paper focuses on analyzing solar radiation affections to the cold space calibration source while the satellite is in lunar orbit. We get the following results: 1. Solar radiation affections are maximal when the satellite is right facing the sun and the maximal brightness temperatures which close to the original antenna temperature T are 86.3200, 85.6700, 31.0020, 29.8905 K, respectively. 2. The incidence of solar radiation affections in forward-flight is smaller than in sideward-flight, and the affections fluctuate rapidly in forward-flight when reaching to and leaving from the peak value. But when in sideward-flight, they are smoothly descending all the time. 3. The solar radiation affections to channel 1 (3 GHz) and channel 2 (7.8 GHz) are almost as three times high as to the other two channels. 4. The affections to E plane, H plane and 45 plane of the same channel are quite similar. These results not only provide important theoretical reference to Microwave Detector’s calibration, but also would be useful when observing the earth in future. |
学科主题 | 微波遥感 |
收录类别 | SCI |
原文出处 | http://www.sciencedirect.com/science?_ob=MImg&_imagekey=B6V3S-4NG3TDJ-6-H&_cdi=5738&_user=1999492&_pii=S0273117707003468&_orig=search&_coverDate=07%2F18%2F2008&_sk=999579997&view=c&wchp=dGLzVzb-zSkzV&md5=a503915d794baf11245aebbe6ed26f04&ie=/sdarticle.pdf |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.cssar.ac.cn/handle/122/1809] |
专题 | 国家空间科学中心_微波遥感部 |
推荐引用方式 GB/T 7714 | Zhang, H. Y.,Zhang, X. H.,Yang, J. L.. The analysis of affections to the cold space calibration source of ChangE-1 payload Microwave Detector[J]. Advances in Space Research,2008,42(2):350-357. |
APA | Zhang, H. Y.,Zhang, X. H.,&Yang, J. L..(2008).The analysis of affections to the cold space calibration source of ChangE-1 payload Microwave Detector.Advances in Space Research,42(2),350-357. |
MLA | Zhang, H. Y.,et al."The analysis of affections to the cold space calibration source of ChangE-1 payload Microwave Detector".Advances in Space Research 42.2(2008):350-357. |