Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources | |
Mao, JY ; Chen, LM ; Hudson, LT ; Seely, JF ; Zhang, L ; Sun, YQ ; Lin, XX ; Zhang, J | |
刊名 | REVIEW OF SCIENTIFIC INSTRUMENTS |
2012 | |
卷号 | 83期号:4 |
关键词 | K-ALPHA SOLID INTERACTIONS EMISSION TARGET PULSE SPECTROSCOPY GENERATION DETECTORS PLASMAS PLATE |
ISSN号 | 0034-6748 |
通讯作者 | Chen, LM: CAS, Beijing Natl Lab Condensed Matter Phys, Inst Phys, Beijing 100190, Peoples R China. |
中文摘要 | In the pursuit of novel, laser-produced x-ray sources for medical imaging applications, appropriate instrumental diagnostics need to be developed concurrently. A type of transmission crystal spectroscopy has previously been demonstrated as a survey tool for sources produced by high-power and high-energy lasers. The present work demonstrates the extension of this method into the study of medium-intensity laser driven hard x-ray sources with a design that preserves resolving power while maintaining high sensitivity. Specifically, spectroscopic measurements of characteristic K alpha and K beta emissions were studied from Mo targets irradiated by a 100 fs, 200 mJ, Ti: sapphire laser with intensity of 10(17) W/cm(2) to 10(18) W/cm(2) per shot. Using a transmission curved crystal spectrometer and off-Rowland circle imaging, resolving powers (E/Delta E) of around 300 for Mo K alpha(2) at 17.37 keV were obtained with an end-to-end spectrometer efficiency of (1.13 +/- 0.10) x 10 (5). This sensitivity is sufficient for registering x-ray lines with high signal to background from targets following irradiation by a single laser pulse, demonstrating the utility of this method in the study of the development of medium-intensity laser driven x-ray sources. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3700212] |
收录类别 | SCI |
资助信息 | National Natural Science Foundation of China (NSFC) [60878014, 10974249, 10735050, 10925421, 10734130, 10935002]; Office of Naval Research |
语种 | 英语 |
公开日期 | 2013-09-17 |
内容类型 | 期刊论文 |
源URL | [http://ir.iphy.ac.cn/handle/311004/33912] |
专题 | 物理研究所_物理所公开发表论文_物理所公开发表论文_期刊论文 |
推荐引用方式 GB/T 7714 | Mao, JY,Chen, LM,Hudson, LT,et al. Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2012,83(4). |
APA | Mao, JY.,Chen, LM.,Hudson, LT.,Seely, JF.,Zhang, L.,...&Zhang, J.(2012).Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources.REVIEW OF SCIENTIFIC INSTRUMENTS,83(4). |
MLA | Mao, JY,et al."Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources".REVIEW OF SCIENTIFIC INSTRUMENTS 83.4(2012). |