Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS | |
Cheng, Xuansheng1,2; Jing, Wei1,2; Li, Xinlei2; Lu, Changde3 | |
刊名 | EARTHQUAKES AND STRUCTURES |
2018-08 | |
卷号 | 15期号:2页码:133-144 |
关键词 | sliding isolation concrete rectangular liquid-storage structure limiting device shaking table test dynamic response |
ISSN号 | 2092-7614 |
DOI | 10.12989/eas.2018.15.2.133 |
英文摘要 | To study the effectiveness of sliding isolation in a CRLSS (concrete rectangular liquid-storage structure) and develop a reasonable limiting-device method, dynamic responses of non-isolation, sliding isolation with spring limiting-devices and sliding isolation with steel bar limiting-devices are comparatively studied by shaking table test. The seismic response reduction advantage of sliding isolation for concrete liquid-storage structures is discussed, and the effect of the limiting-device type on system dynamic responses is analyzed. The results show that the dynamic responses of sliding isolation CRLSS with steel bar-limiting devices are significantly smaller than that of sliding isolation CRLSS with spring-limiting devices. The structure acceleration and liquid sloshing wave height are greatly influenced by spring-limiting devices. The acceleration of the structure in this case is close to or greater than that of a non-isolated structure. Liquid sloshing shows stronger nonlinear characteristics. On the other hand, sliding isolation with steel bar-limiting devices has a good control effect on the structural dynamic response and the liquid sloshing height simultaneously. Thus, a limiting device is an important factor affecting the seismic response reduction effect of sliding isolation. To take full advantage of sliding isolation in a concrete liquid-storage structure, a reasonable design of the limiting device is particularly important. |
WOS研究方向 | Engineering |
语种 | 英语 |
出版者 | TECHNO-PRESS |
WOS记录号 | WOS:000442693500003 |
状态 | 已发表 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.223/handle/2XXMBERH/32528] |
专题 | 土木工程学院 |
通讯作者 | Cheng, Xuansheng; Jing, Wei |
作者单位 | 1.Lanzhou Univ Technol, Westem Engn Res Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Gansu, Peoples R China 2.Lanzhou Univ Technol, Key Lab Disaster Prevent & Mitigat Civil Engn Gan, Lanzhou 730050, Gansu, Peoples R China 3.China Railway 21 Bur Grp Co LTD, Engn Co LTD 2, Lanzhou 730070, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Cheng, Xuansheng,Jing, Wei,Li, Xinlei,et al. Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS[J]. EARTHQUAKES AND STRUCTURES,2018,15(2):133-144. |
APA | Cheng, Xuansheng,Jing, Wei,Li, Xinlei,&Lu, Changde.(2018).Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS.EARTHQUAKES AND STRUCTURES,15(2),133-144. |
MLA | Cheng, Xuansheng,et al."Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS".EARTHQUAKES AND STRUCTURES 15.2(2018):133-144. |