Optimization and verification of dynamic flow balance valve structure | |
Li, Shuxun1,2; Wu, Hanlin1,2; Li, Zhong1,2; Shen, Henyun1,2; Ye, Chen3 | |
刊名 | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology |
2021-07-30 | |
卷号 | 53期号:7页码:108-115 |
关键词 | Electromagnetic wave attenuation Flow control Large eddy simulation Numerical methods Reels Turbulence models Compensation coefficients Compensation factor Control accuracy Correction method Flow field simulation Optimization method Pressure differences Pressure pulsation |
ISSN号 | 03676234 |
DOI | 10.11918/202006055 |
英文摘要 | Aiming at the problem of low flow control accuracy of the dynamic flow balance valve, based on the orifice flow and concentric annular gap flow equations, the spool opening profile was initially designed, and the pressure difference compensation coefficient factor correction method was proposed to optimize and modify the existing profile formula. Based on the large eddy simulation (LES) turbulence model, the flow control accuracy and flow accuracy error of the dynamic flow balance valve before and after optimization were studied by numerical simulation, the influence of the valve core opening profile on the pressure pulsation intensity was compared and analyzed, and a flow test bench was built to verify the proposed optimization method. The results show that the pressure difference compensation factor correction method to optimize the spool opening profile can effectively reduce the pressure pulsation intensity of the spool end face, and improve the flow control accuracy of the dynamic flow balance valve to 3.7%. The flow field simulation calculation and the experimental results basically coincide with the trend. © 2021, Editorial Board of Journal of Harbin Institute of Technology. All right reserved. |
语种 | 中文 |
出版者 | Harbin Institute of Technology |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/151076] |
专题 | 石油化工学院 土木工程学院 |
作者单位 | 1.College of Petrochemical Technology, Lanzhou University of Technology, Lanzhou; 730050, China; 2.Machinery Industry Pump and Special Valve Engineering Research Center, Lanzhou; 730050, China; 3.Zhejiang Dunan Valve CO., LTD., Zhuji; 311800, China |
推荐引用方式 GB/T 7714 | Li, Shuxun,Wu, Hanlin,Li, Zhong,et al. Optimization and verification of dynamic flow balance valve structure[J]. Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology,2021,53(7):108-115. |
APA | Li, Shuxun,Wu, Hanlin,Li, Zhong,Shen, Henyun,&Ye, Chen.(2021).Optimization and verification of dynamic flow balance valve structure.Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology,53(7),108-115. |
MLA | Li, Shuxun,et al."Optimization and verification of dynamic flow balance valve structure".Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology 53.7(2021):108-115. |