Shaking table test of combination isolation plate-shell integrated concrete liquid-storage structure | |
Qi, Lei1,2; Cheng, Xuansheng1,2; Zhang, Shanglong2; Wang, Fuqiang2; Xia, Peiyan2 | |
刊名 | Canadian Journal of Civil Engineering |
2022 | |
卷号 | 49期号:6页码:1014-1025 |
关键词 | Earthquakes Hydrodynamics Liquid sloshing Plates (structural components) Shape-memory alloy Acceleration response Combination isolation system Hydrodynamic pressure Isolation systems Liquid storage Liquid-storage structure Seismic Performance Shaking table tests Storage structures Test models |
ISSN号 | 0315-1468 |
DOI | 10.1139/cjce-2021-0309 |
英文摘要 | To obtain the seismic performance of plate-shell integrated concrete liquid-storage structures (PSICLSS), a scale test model was built for shaking table testing. A combination isolation layer is proposed, and the dynamic responses of non-isolation and combination isolation PSICLSS under unidirectional and bidirectional earthquakes were tested. The results show that the combination isolation layer can change the spectral characteristics of the input acceleration, reducing the acceleration response and displacement of the structure, but it will increase the hydrodynamic pressure and liquid sloshing height. Under earthquake action, the liquid sloshing of combination isolation PSICLSS clearly appears as a nonlinear splash phenomenon. When considering the vertical earthquake, the horizontal acceleration response of PSICLSS and the liquid sloshing height change little, the peak hydrodynamic pressure changes significantly, and the peak position also changes. The maximum displacement of the isolation layer increases, but the residual displacement decreases. © 2021 The Author(s). |
语种 | 英语 |
出版者 | Canadian Science Publishing |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/158458] |
专题 | 土木工程学院 机电工程学院 |
作者单位 | 1.Western Engineering Research Center of Disaster Mitigation in Civil Engineering of the Ministry of Education, Lanzhou University of Technology, Lanzhou; 730050, China; 2.Key Laboratory of Disaster Prevention and Mitigation in Civil Engineering of Gansu Province, Lanzhou Universityof Technology, Lanzhou; 730050, China |
推荐引用方式 GB/T 7714 | Qi, Lei,Cheng, Xuansheng,Zhang, Shanglong,et al. Shaking table test of combination isolation plate-shell integrated concrete liquid-storage structure[J]. Canadian Journal of Civil Engineering,2022,49(6):1014-1025. |
APA | Qi, Lei,Cheng, Xuansheng,Zhang, Shanglong,Wang, Fuqiang,&Xia, Peiyan.(2022).Shaking table test of combination isolation plate-shell integrated concrete liquid-storage structure.Canadian Journal of Civil Engineering,49(6),1014-1025. |
MLA | Qi, Lei,et al."Shaking table test of combination isolation plate-shell integrated concrete liquid-storage structure".Canadian Journal of Civil Engineering 49.6(2022):1014-1025. |