Research on Optimized Energy Saving Control System of VAV Air Conditioning System | |
Jiang Hongmei1,2; Li Zhanming1,2; Tang Weiqiang1,2 | |
2019 | |
卷号 | 237 |
DOI | 10.1088/1755-1315/237/4/042015 |
英文摘要 | VAV air conditioning system has complex structure, huge scale, many variables, strong coupling and various uncertainties The traditional automatic control methods adopt the method that the controlled parameters of the system are fixed, which can satisfy the stable operation of the system, but it will bring a great waste of energy. In this paper, the optimization objectives and constraints to minimize energy consumption are proposed, and the optimization model of central air conditioning system is established. The optimization objective of VAV is minimum energy consumption.It can meet the comfort and stability, reduce the energy consumption of the system and achieve the best energy-saving effect. |
会议录 | 4TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING
![]() |
会议录出版者 | IOP PUBLISHING LTD |
会议录出版地 | DIRAC HOUSE, TEMPLE BACK, BRISTOL BS1 6BE, ENGLAND |
语种 | 英语 |
资助项目 | Key Laboratory of Gansu Advanced Control for Industrial Processes, China[XJK201813] |
WOS研究方向 | Energy & Fuels ; Engineering |
WOS记录号 | WOS:000472788600206 |
内容类型 | 会议论文 |
源URL | [http://119.78.100.223/handle/2XXMBERH/36099] ![]() |
专题 | 电气工程与信息工程学院 |
通讯作者 | Jiang Hongmei |
作者单位 | 1.Lanzhou Univ Technol, Coll Elect & Informat Engn, Lanzhou, Gansu, Peoples R China 2.Lanzhou Univ Technol, Key Lab Gansu Adv Control Ind Proc, Lanzhou, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Jiang Hongmei,Li Zhanming,Tang Weiqiang. Research on Optimized Energy Saving Control System of VAV Air Conditioning System[C]. 见:. |