Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system | |
Zhang, D.1; Wu, Q.B.1,2; Li, J.P.1; Kong, X.Q.3 | |
刊名 | Applied Thermal Engineering
![]() |
2014-12-05 | |
卷号 | 73期号:1页码:522-528 |
关键词 | Coefficient of performance Expansion Heat pump systems Pumps Refrigeration Direct expansion Mathematical calculations Refrigerant charge Refrigerant distributions Refrigerant mass charge Solar assisted heat pump Solar assisted heat pump systems Structural parameter |
ISSN号 | 13594311 |
DOI | 10.1016/j.applthermaleng.2014.07.077 |
英文摘要 | The direct-expansion solar-assisted heat pump (DX-SAHP) is widely studied as a refrigeration system, which can supply hot water for domestic use during the whole year. The system refrigerant charge and structure parameters are believed to have a great effect on the cycling thermal performance. The refrigerant mass charge including two-phase and single-phase in heat exchangers and pipes is calculated with distributed and lumped parameter approach mathematical models, respectively. Based on the system simulation program, the refrigerant distribution characteristics and system performance under varied structural parameters are obtained. The mathematical calculation results show that the 70%-80% refrigerant charge exists in the condenser and collector; the optimum refrigerant charge, solar collector area, condenser pipe length and condenser internal diameter for the system are 1.65-1.75 kg, 6.0 m2, 70 m and 9 mm, respectively. In the optimum parameters, the better system performance and feasible cost can be achieved. © 2014 Elsevier Ltd. All rights reserved. |
WOS研究方向 | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
语种 | 英语 |
出版者 | Elsevier Ltd |
WOS记录号 | WOS:000346543400053 |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/150438] ![]() |
专题 | 兰州理工大学 |
作者单位 | 1.School of Energy and Power Engineering, Lanzhou University of Technology, Lanzhou 730050, China; 2.Cold and Arid Regions Environmental Engineering Research Institute, Chinese Academy of Sciences, Lanzhou 730000, China; 3.School of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China |
推荐引用方式 GB/T 7714 | Zhang, D.,Wu, Q.B.,Li, J.P.,et al. Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system[J]. Applied Thermal Engineering,2014,73(1):522-528. |
APA | Zhang, D.,Wu, Q.B.,Li, J.P.,&Kong, X.Q..(2014).Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system.Applied Thermal Engineering,73(1),522-528. |
MLA | Zhang, D.,et al."Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system".Applied Thermal Engineering 73.1(2014):522-528. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论