Polystyrene-type uniform porous microsphere enables high resolution and low-pressure chromatography of natural products - A case study with icariin purification | |
Sun, HH; Li, XN; Ma, GH; Su, ZG | |
刊名 | CHROMATOGRAPHIA |
2005 | |
卷号 | 61期号:1-2页码:9-15 |
关键词 | column liquid chromatography icariin membrane emulsification uniform porous microsphere |
ISSN号 | 0009-5893 |
其他题名 | Chromatographia |
中文摘要 | An efficient low-pressure preparative chromatography for purification of icariin from crude extract has been developed by employing a novel uniform porous microsphere, named PST, as packing material. A comparison was made between the PST medium and a commercially available silica-based C-18 medium on their column chromatographic performance. The PST column demonstrated a higher resolution and better selectivity than the C-18 column. Crude extract of 20% icariin can be purified to 90.0% with the recovery of 99.9% and column loadability of 2.5 mg-mL(-1) medium on the PST column under the optimized condition. After crystallization the purity of icariin can reach more than 98% with a total recovery of 93%. The product structure was determined by means of UV, IR, MS and NMR. |
英文摘要 | An efficient low-pressure preparative chromatography for purification of icariin from crude extract has been developed by employing a novel uniform porous microsphere, named PST, as packing material. A comparison was made between the PST medium and a commercially available silica-based C-18 medium on their column chromatographic performance. The PST column demonstrated a higher resolution and better selectivity than the C-18 column. Crude extract of 20% icariin can be purified to 90.0% with the recovery of 99.9% and column loadability of 2.5 mg-mL(-1) medium on the PST column under the optimized condition. After crystallization the purity of icariin can reach more than 98% with a total recovery of 93%. The product structure was determined by means of UV, IR, MS and NMR. |
WOS标题词 | Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences |
类目[WOS] | Biochemical Research Methods ; Chemistry, Analytical |
研究领域[WOS] | Biochemistry & Molecular Biology ; Chemistry |
关键词[WOS] | ANTI-HYPOXIA/REOXYGENATION AGENTS ; LIQUID-CHROMATOGRAPHY ; FLAVONOL GLYCOSIDES ; RETENTION ; COLUMNS ; CELLS |
收录类别 | SCI |
原文出处 | |
语种 | 英语 |
WOS记录号 | WOS:000226506000002 |
公开日期 | 2013-10-25 |
内容类型 | 期刊论文 |
版本 | 出版稿 |
源URL | [http://ir.ipe.ac.cn/handle/122111/4224] |
专题 | 过程工程研究所_研究所(批量导入) |
作者单位 | 1.Chinese Acad Sci, Inst Proc Engn, Natl Key Lab Biochem Engn, Beijing 100080, Peoples R China 2.Beijing Inst Chem Technol, Sch Chem Engn, Beijing 100029, Peoples R China |
推荐引用方式 GB/T 7714 | Sun, HH,Li, XN,Ma, GH,et al. Polystyrene-type uniform porous microsphere enables high resolution and low-pressure chromatography of natural products - A case study with icariin purification[J]. CHROMATOGRAPHIA,2005,61(1-2):9-15. |
APA | Sun, HH,Li, XN,Ma, GH,&Su, ZG.(2005).Polystyrene-type uniform porous microsphere enables high resolution and low-pressure chromatography of natural products - A case study with icariin purification.CHROMATOGRAPHIA,61(1-2),9-15. |
MLA | Sun, HH,et al."Polystyrene-type uniform porous microsphere enables high resolution and low-pressure chromatography of natural products - A case study with icariin purification".CHROMATOGRAPHIA 61.1-2(2005):9-15. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论