The preparation of a flexible AuNP modified carbon cloth electrode and its application in electrochemical detection of Hg(ii) by continuous flow in environmental water | |
Guan, Peng1,2; Guo, Peng-Ran1; Liu, Ning1; Zhang, Fang1; Lei, Yong-Qian1 | |
刊名 | ANALYST |
2018-09-21 | |
卷号 | 143期号:18页码:4436-4441 |
ISSN号 | 0003-2654 |
DOI | 10.1039/c8an01284a |
英文摘要 | In this article, a carbon cloth composite electrode modified with gold nanoparticles (AuNPs) was prepared by a facile in situ electrodeposition method and applied to the detection of mercury ions in water. With the optimized electrochemical detection conditions and methods, the limit of detection (LOD) was 0.6 g L-1 with the linearity ranging from 2 to 200 g L-1 by the SWSV detection method, and the electrode showed good repeatability after many cycles. Based on this detection method, a continuous flow electrochemical detection system was constructed and applied to the detection of Hg ions in environmental water samples. The standard addition experimental results of two real water samples with an addition level of 10 and 50 g L-1 showed that the recoveries were between 92.4% and 108.9% with RSDs from 2.01% to 3.22%. These results showed the same performance as that of the ZAAS mercury detection method (recovery: 94-102.4%, RSD 2.09-5.4%). Compared with other electrode materials, a shorter detection time, a wider linear range and high stability with a similar LOD can be achieved by a continuous flow detection method by using the composite electrode. The established continuous flow electrochemical detection system would have promising application in online and real-time detection of heavy metals in environmental water. |
资助项目 | National Natural Science Foundation of China[21707128][21777150] ; Science and Technology Planning project of Guangdong Province, China[2016B020240006][2015A020218001][2017A040405040] ; Science and Technology Program of Guangzhou, China[201803030042] ; GDAS' Special Project of Science and Technology Development[2018GDASCX-0921] |
WOS研究方向 | Chemistry |
语种 | 英语 |
出版者 | ROYAL SOC CHEMISTRY |
WOS记录号 | WOS:000444553400026 |
状态 | 已发表 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.223/handle/2XXMBERH/32449] |
专题 | 兰州理工大学 石油化工学院 |
通讯作者 | Lei, Yong-Qian |
作者单位 | 1.Guangdong Inst Anal, Guangdong Prov Key Lab Emergency Test Dangerous C, Guangdong Engn Technol Res Ctr On Line Monitoring, Guangzhou 510070, Guangdong, Peoples R China 2.Lanzhou Univ Technol, Coll Petrochem Technol, Lanzhou 730050, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Guan, Peng,Guo, Peng-Ran,Liu, Ning,et al. The preparation of a flexible AuNP modified carbon cloth electrode and its application in electrochemical detection of Hg(ii) by continuous flow in environmental water[J]. ANALYST,2018,143(18):4436-4441. |
APA | Guan, Peng,Guo, Peng-Ran,Liu, Ning,Zhang, Fang,&Lei, Yong-Qian.(2018).The preparation of a flexible AuNP modified carbon cloth electrode and its application in electrochemical detection of Hg(ii) by continuous flow in environmental water.ANALYST,143(18),4436-4441. |
MLA | Guan, Peng,et al."The preparation of a flexible AuNP modified carbon cloth electrode and its application in electrochemical detection of Hg(ii) by continuous flow in environmental water".ANALYST 143.18(2018):4436-4441. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论