Sparse-aperture photonics-integrated interferometer (spin) imaging system: Structural design and imaging quality analysis
T. Chen; X. Zeng; Y. Bai; Z. Zhang; Y. Wang; F. Zhang and X. Zhang
刊名Optics Express
2021
卷号29期号:24页码:39256-39270
ISSN号10944087
DOI10.1364/OE.444421
英文摘要The burgeoning field of astrophotonics, the interface between astronomy and photonics, is redefining astronomical instrumentation to replace traditional bulk optical systems with integrated optics. This drives the development of a new promising photonics-integrated interferometric imaging technique, called the segmented planar imaging detector for electro-optical reconnaissance (SPIDER). Compared to conventional imaging systems, SPIDER can reduce the size, weight, and power (SWaP) by one to two orders of magnitude for an equivalent imaging resolution in virtue of photonics-integrated technology. However, SPIDER has a dense lens distribution and tens of separated narrow wavebands demultiplexed by array waveguide gratings. In this paper, we developed a new simplified sparse-aperture photonics-integrated interferometer (SPIN) imaging system. The SPIN imaging system was no more a Michelson configuration interferometer as SPIDER and was designed as a Fizeau configuration interferometer imaging system. This transfer of configuration type affords a more concise structure; the SPIN was designed with much less apertures and fewer wavebands than those of SPIDER. Further, the SPIN yields enhanced modulation transfer function and imaging quality with equivalent aperture diameter, compared with SPIDER. The main barrier of this transfer is the elimination of coupling restriction at the tip of a waveguide, namely the apodization effect. This effect, which is caused by the coupling effect between Fourier lens and waveguide, hinders SPIN imaging systems from getting finer resolution. However, a microscope could be used to eliminate this effect. Moreover, a waveguide array is used to receive these finer details and enlarges the field of view in SPIN. The coupling efficiency of the waveguides and crosstalk errors between waveguides of array were analyzed, which are important for proper parameters setting in SPIN imaging system. Based on these analyses, the imaging principle was derived and a hyper-Laplacian-based imaging reconstruction algorithm was developed. A simulation of the SPIN imaging system with seven apertures and one imaging waveband demonstrated the high imaging quality. 2021 Optica Publishing Group.
URL标识查看原文
内容类型期刊论文
源URL[http://ir.ciomp.ac.cn/handle/181722/65643]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
T. Chen,X. Zeng,Y. Bai,et al. Sparse-aperture photonics-integrated interferometer (spin) imaging system: Structural design and imaging quality analysis[J]. Optics Express,2021,29(24):39256-39270.
APA T. Chen,X. Zeng,Y. Bai,Z. Zhang,Y. Wang,&F. Zhang and X. Zhang.(2021).Sparse-aperture photonics-integrated interferometer (spin) imaging system: Structural design and imaging quality analysis.Optics Express,29(24),39256-39270.
MLA T. Chen,et al."Sparse-aperture photonics-integrated interferometer (spin) imaging system: Structural design and imaging quality analysis".Optics Express 29.24(2021):39256-39270.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace