Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system
Yang, Min1; Zhang, Jianhai2; Yuan, Maodan2; Li, Xingdong3; Liu, Wenli3; Meng, Fanyong4; Song, Sung-Jin2; Wei, Dongbo1
刊名NDT & E INTERNATIONAL
2012-11-01
卷号52期号:0页码:16-22
关键词Computed laminography (CL) Geometrical calibration Origin of projection coordinates Over-determined equation set
ISSN号0963-8695
通讯作者Yang, M
英文摘要Computed laminography (CL) is different from conventional computed tomography(CT) for its specialization in testing plate-type structures, such as integrated circuit boards (ICB), multilayer printing circuit boards (MPCB), and ball grid arrays (BGA). It adopts a different scanning way to successfully produce cross-sectional images of the plate-type objects, while the conventional CT cannot be used. According to the CL reconstruction algorithm, precise determination of the origin of the projection coordinate system is the first step during cone-beam CL scanning system calibration. But unfortunately, for the practical CL scanning system, it is impossible to measure the position of the X-ray focus projection by direct means. A new method to determine the X-ray focus projection coordinates with high accuracy is proposed. Firstly the angle between the central X-ray and the axis of rotation is set to zero by rotating the X-ray source and detector synchronously. Acquiring digital radiography (DR) images of several spherical objects at two geometrical magnification ratio positions in the cone X-ray beam, the two DR images are combined to one image, on the base of which image processing methods are employed to get the center points of each projection of the spherical object. And every two-positioned center points of the same spherical object determine a line, so all couples of projection centers of all the spherical objects construct a group of lines, mathematically an over-determined equation set. After solving the over-determined equation, the X-ray focus projection coordinates are finally obtained. The experimental results prove that the accuracy of this method can satisfy the requirements of the practical scanning system, meanwhile it is feasible to realize. (C) 2012 Published by Elsevier Ltd.
WOS标题词Science & Technology ; Technology
类目[WOS]Materials Science, Characterization & Testing
研究领域[WOS]Materials Science
关键词[WOS]GEOMETRICAL CALIBRATION ; CT ; OPTIMIZATION ; TOMOGRAPHY ; PARAMETERS
收录类别SCI
语种英语
WOS记录号WOS:000310424500003
公开日期2013-10-11
内容类型期刊论文
版本出版稿
源URL[http://ir.ipe.ac.cn/handle/122111/3182]  
专题过程工程研究所_多相复杂系统国家重点实验室
作者单位1.Beijing Univ Aeronaut & Astronaut, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
2.Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, South Korea
3.Natl Inst Metrol, Beijing 100013, Peoples R China
4.Chinese Acad Sci, Inst Proc Engn, State Key Lab Multiphase Complex Syst, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Yang, Min,Zhang, Jianhai,Yuan, Maodan,et al. Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system[J]. NDT & E INTERNATIONAL,2012,52(0):16-22.
APA Yang, Min.,Zhang, Jianhai.,Yuan, Maodan.,Li, Xingdong.,Liu, Wenli.,...&Wei, Dongbo.(2012).Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system.NDT & E INTERNATIONAL,52(0),16-22.
MLA Yang, Min,et al."Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system".NDT & E INTERNATIONAL 52.0(2012):16-22.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace