Is Anoxic Operation Effective to Control Nitrate Build-Up and Sludge Loss for the Combined Partial Nitritation and Anammox (CPNA) Process?
Wang, Hongyan; Wang, Yuanyue; Zhang, Junya; Sui, Qianwen; Hu, Dazhou; Zuo, Fumin; Wei, Yuansong
刊名PROCESSES
2020-09
卷号8期号:9页码:1-8
关键词CPNA start-up nitrate build-up sludge loss
英文摘要There were three main issues of long start-up period, nitrate build-up and sludge loss during the operation of combined partial-nitritation anammox (CPNA). To fully start up the CPNA reactor, the fast achievement of partial-nitritation (PN) was the first step. Firstly, the PN process was successfully achieved within 22 days by 2 mg.L(-1)hydroxylamine (NH2OH) addition and online intermittent aeration control at 0.2 similar to 0.3 mg.L(-1)dissolved oxygen (DO). Then, a novel strategy of adding anoxic stirring phase between feeding and aeration period during CPNA operation was applied. It was shown effective to control nitrate build-up since the mole ratio of NO3--N production and NH4+-N removed (MNRR) was mostly below 15%. Also, the procedure adjustment was proven useful to alleviate sludge loss by sustaining filamentous bacteria that could act as biomass framework and reduce nitrate substrate. The filamentous denitrifying bacteria could cause sludge bulking. The total nitrogen removal rate (TNRR) varied from 0.20 to 0.45 kg.m(-3).d(-1)during CPNA operation. In Stage III, after adding anoxic stirring phase, the abundance of nitrogen transformation functional microorganism's nitrite oxidizing bacteria (NOB) was below 1.6%, which was one order of magnitude lower than Anammox and ammonia oxidizing bacteria (AOB).
内容类型期刊论文
源URL[http://ir.rcees.ac.cn/handle/311016/45048]  
专题生态环境研究中心_水污染控制实验室
推荐引用方式
GB/T 7714
Wang, Hongyan,Wang, Yuanyue,Zhang, Junya,et al. Is Anoxic Operation Effective to Control Nitrate Build-Up and Sludge Loss for the Combined Partial Nitritation and Anammox (CPNA) Process?[J]. PROCESSES,2020,8(9):1-8.
APA Wang, Hongyan.,Wang, Yuanyue.,Zhang, Junya.,Sui, Qianwen.,Hu, Dazhou.,...&Wei, Yuansong.(2020).Is Anoxic Operation Effective to Control Nitrate Build-Up and Sludge Loss for the Combined Partial Nitritation and Anammox (CPNA) Process?.PROCESSES,8(9),1-8.
MLA Wang, Hongyan,et al."Is Anoxic Operation Effective to Control Nitrate Build-Up and Sludge Loss for the Combined Partial Nitritation and Anammox (CPNA) Process?".PROCESSES 8.9(2020):1-8.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。