Simultaneous passive sampling of hydrophilic and hydrophobic emerging organic contaminants in water
Gao, Xiaozhong; Xu, Yiping; Ma, Mei; Rao, Kaifeng; Wang, Zijian
刊名ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY
2019-08-30
卷号178页码:25-32
关键词Passive sampling Organophosphorus flame retardants Hydrophilic organic contaminants Hydrophobic organic contaminants Time-weighted average concentration Freely dissolved concentration
ISSN号0147-6513
英文摘要Passive sampling techniques have been considered robust tools for monitoring freely dissolved concentrations of contaminants in aquatic systems. However, few passive samplers are currently available for the simultaneous sampling of both hydrophilic and hydrophobic chemicals. In this study, we developed a novel passive sampler (a hydrophilic-lipophilic balance sorbent-embedded cellulose acetate membrane (HECAM)) for estimating the time -weighted average (TWA) concentrations of both hydrophilic and hydrophobic organic contaminants in water. In our laboratorial controlled dynamic experiments, the accumulation results of thirty-seven target chemicals (including organophosphorus flame retardants, phenols, estrogens, organophosphorus pesticides, and triazine herbicides) with a wide polarity range (1.44 < log K-ow < 9.49) in the HECAM followed first -order kinetics well, and the passive sampling parameters were estimated successfully. The estimated sampling rates for the target chemicals in the HECAM ranged from 0.14 to 6.90 L d(-1) in the laboratory experiment, and the log K-sw (equilibrium partition coefficient between the sampler and water) values ranged from 2.75 to 6.00. The HECAM exhibited high sampling rate for moderately hydrophilic and moderately hydrophobic chemicals. The field validation study in an urban river resulted in the detection of four target chemicals (tris(chloroisopropyl) phosphate, tris(1,3-dichloroisopropyl)phosphate, prometryn, and 4-tert-octylphenol) by the HECAM at estimated TWA concentrations of 10.9-179.5 ng L-1, which were in agreement with the measured levels found in traditional grab samples by solid -phase extraction. In summary, both the laboratory tests and field deployment showed practicable results for the HECAM passive sampling, which suggests that it is an efficient approach for simultaneous monitoring of hydrophilic and hydrophobic organic contaminants in water.
内容类型期刊论文
源URL[http://ir.rcees.ac.cn/handle/311016/43524]  
专题生态环境研究中心_中国科学院饮用水科学与技术重点实验室
作者单位1.Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
2.Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Aquat Chem, Beijing 100085, Peoples R China
推荐引用方式
GB/T 7714
Gao, Xiaozhong,Xu, Yiping,Ma, Mei,et al. Simultaneous passive sampling of hydrophilic and hydrophobic emerging organic contaminants in water[J]. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY,2019,178:25-32.
APA Gao, Xiaozhong,Xu, Yiping,Ma, Mei,Rao, Kaifeng,&Wang, Zijian.(2019).Simultaneous passive sampling of hydrophilic and hydrophobic emerging organic contaminants in water.ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY,178,25-32.
MLA Gao, Xiaozhong,et al."Simultaneous passive sampling of hydrophilic and hydrophobic emerging organic contaminants in water".ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 178(2019):25-32.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace