Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak
Su, Pengjuan2; Zhong, Heng2; Tan, Yi2; Gao, Zhe2; Zai, Yingqi2; Liu, Haiqing1; Zeng, Long1; Zhu, Xiang3; Ling, Bili1; Cheng, Zhengbo2
刊名REVIEW OF SCIENTIFIC INSTRUMENTS
2021-04-01
卷号92
ISSN号0034-6748
DOI10.1063/5.0043667
通讯作者Su, Pengjuan(spj18@mails.tsimghua.edu.cn)
英文摘要A five-channel microwave interferometer with high temporal resolution and high phase resolution has been developed for measuring electron density profiles and fluctuations on the Sino-UNIted Spherical Tokamak. A correction algorithm, based on the low signal amplitude detection, is proposed to eliminate the fringe jump errors. The correction algorithm achieves an accuracy of 92%. The density profile is reconstructed through the Park-matrix method, with the geometry of magnetic surfaces calculated by the equilibrium fitting. The reconstructed density profiles for discharges with supersonic molecular beam injection are in good agreement with the results of another 94 GHz single-channel horizontal interferometer and the Langmuir probes. The temporal resolution of the system is 0.5 mu s and the line-integrated electron density resolution is 1 x 10(15) m(-2), which benefits from the single sideband modulation technique. Therefore, the multichannel interferometer system is capable of studying the details of the high-frequency (up to 200 kHz) density fluctuation such as that in the minor disruption event.
资助项目NSFC[11827810] ; NSFC[11875177] ; IAEA CRP[22733] ; Science Challenge Project[TZ2016005]
WOS研究方向Instruments & Instrumentation ; Physics
语种英语
出版者AMER INST PHYSICS
WOS记录号WOS:000639895300004
资助机构NSFC ; IAEA CRP ; Science Challenge Project
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/122023]  
专题中国科学院合肥物质科学研究院
通讯作者Su, Pengjuan
作者单位1.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
2.Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
3.Shenzhen Univ, Adv Energy Res Ctr, Shenzhen 518060, Peoples R China
推荐引用方式
GB/T 7714
Su, Pengjuan,Zhong, Heng,Tan, Yi,et al. Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2021,92.
APA Su, Pengjuan.,Zhong, Heng.,Tan, Yi.,Gao, Zhe.,Zai, Yingqi.,...&Wang, Binbin.(2021).Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak.REVIEW OF SCIENTIFIC INSTRUMENTS,92.
MLA Su, Pengjuan,et al."Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak".REVIEW OF SCIENTIFIC INSTRUMENTS 92(2021).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace