Uniform manganese-loaded titanium dioxide nanotube arrays for accurate detection of trace Cd2+ in water, soil and tea: Enhanced stability and sensitivity
Jiang, Min1,2,3; Ma, Ming-Jun3,4; Lin, Chu-Hong1,2,3; Yang, Meng1,2,3,4; Fang, Li3,4; Liu, Jin-Huai1,2,3; Zhao, Nan-Jing3,4; Huang, Xing-Jiu1,2,3
刊名CHEMICAL ENGINEERING JOURNAL
2020-11-15
卷号400
关键词Self-organizing and ordered Mn-TiO2 NTAs ECP-LIBS MATLAB Simulation High stability and sensitivity
ISSN号1385-8947
DOI10.1016/j.cej.2020.125972
通讯作者Yang, Meng(myang@iim.ac.cn) ; Zhao, Nan-Jing(njzhao@aiofm.ac.cn) ; Huang, Xing-Jiu(xingjiuhuang@iim.ac.cn)
英文摘要The poor stability of the signal obtained on nonuniform substrate, which results from the obvious difference in the size of ablation spots, the uneven distribution of enriched analytes, and the severe matrix effect, seriously affecting the practical application of electrochemical preconcentration supported laser-induced breakdown spectroscopy (ECP-LIBS). Here, self-organizing and ordered manganese loaded titanium dioxide nanotube arrays (Mn-TiO2 NTAs) on a titanium foil was employed as the working electrode to overcome the problem. The MnTiO2 NTAs were of equal height, hollow-structured and evenly arranged on the electrode, leading to uniform and shallow ablation spots after Gaussian laser irradiation (proven by MATLAB simulation), which reduced the matrix effect. As a result, a high sensitivity of 13347.7 counts mu M-1 and low LOD of 0.01 mu M for Cd2+ were achieved. Most importantly, the self-organizing and ordered Mn-TiO2 NTAs electrode exhibited outstanding stability and reproducibility (relative standard deviation, RSD, was less than 5%), while the Mn-TiO2 electrode modified through the drip coating method showed poor stability (RSD was greater than 20%). The proposed method perfectly achieved the anti-interference and accurate detection of Cd2+ in water, soil and tea.
资助项目National Natural Science Foundation of China[21735005] ; National Natural Science Foundation of China[21802145] ; Natural Science Foundation of Anhui Province[2008085QB79] ; postdoctoral innovation talents supporting project[BX20180311] ; China Postdoctoral Science Foundation[2019 M652220] ; Science and Technology Major Project of Anhui Province[17030801033] ; Key Program of 13th five-year plan, CASHIPS ; Science and Technology Research Project of Anhui Province[1704c0402195] ; One Hundred Person Project of the Chinese Academy of Sciences, China
WOS关键词INDUCED BREAKDOWN SPECTROSCOPY ; ELECTROCHEMICAL DETECTION ; STRIPPING ANALYSIS ; ELEMENTAL ANALYSIS ; FACILE SYNTHESIS ; TIO2 NANOTUBES ; METAL REMOVAL ; SENSOR ; ELECTRODE ; SAMPLES
WOS研究方向Engineering
语种英语
出版者ELSEVIER SCIENCE SA
WOS记录号WOS:000569324500010
资助机构National Natural Science Foundation of China ; Natural Science Foundation of Anhui Province ; postdoctoral innovation talents supporting project ; China Postdoctoral Science Foundation ; Science and Technology Major Project of Anhui Province ; Key Program of 13th five-year plan, CASHIPS ; Science and Technology Research Project of Anhui Province ; One Hundred Person Project of the Chinese Academy of Sciences, China
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/104112]  
专题中国科学院合肥物质科学研究院
通讯作者Yang, Meng; Zhao, Nan-Jing; Huang, Xing-Jiu
作者单位1.Chinese Acad Sci, Key Lab Environm Opt & Technol, Hefei 230031, Peoples R China
2.Chinese Acad Sci, Inst Intelligent Machines, Hefei 230031, Peoples R China
3.Univ Sci & Technol China, Hefei 230026, Peoples R China
4.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei 230031, Peoples R China
推荐引用方式
GB/T 7714
Jiang, Min,Ma, Ming-Jun,Lin, Chu-Hong,et al. Uniform manganese-loaded titanium dioxide nanotube arrays for accurate detection of trace Cd2+ in water, soil and tea: Enhanced stability and sensitivity[J]. CHEMICAL ENGINEERING JOURNAL,2020,400.
APA Jiang, Min.,Ma, Ming-Jun.,Lin, Chu-Hong.,Yang, Meng.,Fang, Li.,...&Huang, Xing-Jiu.(2020).Uniform manganese-loaded titanium dioxide nanotube arrays for accurate detection of trace Cd2+ in water, soil and tea: Enhanced stability and sensitivity.CHEMICAL ENGINEERING JOURNAL,400.
MLA Jiang, Min,et al."Uniform manganese-loaded titanium dioxide nanotube arrays for accurate detection of trace Cd2+ in water, soil and tea: Enhanced stability and sensitivity".CHEMICAL ENGINEERING JOURNAL 400(2020).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace