Determination of serum catecholamine metabolites in neuroblastoma by high performance liquid chromatography with electrochemical detection
Tang, Q M; Xu, X R; Shi, Y Q; Jin, B X
刊名Biomedical chromatography : BMC
1986-02
卷号1期号:1页码:7-11
ISSN号0269-3879
DOI10.1002/bmc.1130010103
文献子类Article
英文摘要A method for determining serum catecholamine metabolites such as vanillylmandelic acid (VMA), 3-methoxy-4-hydroxyphenyl glycol (MHPG) and homovanillic acid (HVA) in neuroblastoma by using high performance liquid chromatography and electrochemical detector is described. The separation of catecholamine metabolites was performed on a reverse phase column with an eluting system containing citric acid-potassium hydrogen phosphate buffer and methanol as the organic modifier. The experimental results showed that VMA and HVA levels in the serum of neuroblastoma patients were 15-30 times higher than that of the normal control group. The same phenomenon also occurred in patients with stage II neuroblastoma. Serum VMA, MHPG and HVA levels reduced to normal in patients suffering from neuroblastoma after surgery. Serum catecholamine metabolites analysed by using HPLC/ECD is more simple, sensitive and reliable than that by usual urine assay and might be used for the diagnosis of neuroblastoma even in early stage.
语种英语
内容类型期刊论文
源URL[http://119.78.100.183/handle/2S10ELR8/266281]  
专题中国科学院上海药物研究所
作者单位Shanghai Institute of Materia Medica, Academia Sinica, China
推荐引用方式
GB/T 7714
Tang, Q M,Xu, X R,Shi, Y Q,et al. Determination of serum catecholamine metabolites in neuroblastoma by high performance liquid chromatography with electrochemical detection[J]. Biomedical chromatography : BMC,1986,1(1):7-11.
APA Tang, Q M,Xu, X R,Shi, Y Q,&Jin, B X.(1986).Determination of serum catecholamine metabolites in neuroblastoma by high performance liquid chromatography with electrochemical detection.Biomedical chromatography : BMC,1(1),7-11.
MLA Tang, Q M,et al."Determination of serum catecholamine metabolites in neuroblastoma by high performance liquid chromatography with electrochemical detection".Biomedical chromatography : BMC 1.1(1986):7-11.