Research on on-board calibration system of Tiangong-2 wide-band imaging spectrometer
Tang Yuyu; Wei Jun; Huang Xiaoxian; Feng Xin; Song Qingjun
2019
关键词Tiangong-2 Imaging Spectrometer Spectral calibration Radiometric calibration Halogen lamp Surface blackbody
DOI10.1007/978-981-13-3501-3_3
英文摘要With the increasing requirements for quantification of in-orbit data products, the research of high-precision calibration system is of vital importance. Based on the research background of Tiangong-2 (TG-2) Wide-band imaging spectrometer payload, a complete scheme of full detection band radiometric and VNIR spectral calibration is proposed in this paper. A full FOV and aperture calibrator with internal reference radiation sources is designed, which consists of pointing mirror, halogen lamp with Pr-Nd glass and surface blackbody, and calibrates by rotating the mirror to point to the lamp and blackbody. The results of in-orbit calibration show that the scheme is reasonable and the calibration accuracy meets the requirements.
内容类型会议论文
源URL[http://202.127.2.71:8080/handle/181331/12336]  
专题上海技术物理研究所_上海技物所
推荐引用方式
GB/T 7714
Tang Yuyu,Wei Jun,Huang Xiaoxian,et al. Research on on-board calibration system of Tiangong-2 wide-band imaging spectrometer[C]. 见:.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace