CORC  > 上海天文台  > 中国科学院上海天文台
Signal Biases Calibration for Precise Orbit Determination of the Chinese Area Positioning System using SLR and C-Band Transfer Ranging Observations
Cao Fen1,2,3; Yang Xuhai2,3; Li Zhigang2,3; Chen Liang2,3; Feng Chugang4
刊名JOURNAL OF NAVIGATION
2016-11-01
卷号69期号:6页码:1234-1246
关键词Geostationary Earth Orbit (Geo) Satellite Signal Biases Calibration Co-location Comparison Method Combined Precise Orbit Determination (Pod)
ISSN号0373-4633
DOI10.1017/S0373463316000205
英文摘要In C-Band transfer measuring systems, the Precise Orbit Determination (POD) precision of Geostationary Earth Orbit (GEO) satellites is limited by signal biases such as the station delay biases, transponder delay biases, the ionospheric delay model bias, etc. In order to improve the POD precision, the signal biases of the Chinese Area Positioning System (CAPS) are calibrated using Satellite Laser Ranging (SLR) and C-Band Transfer Ranging (CBTR) observations. Since the Changchun SLR site and C-Band station are close to each other, the signal biases of the Changchun C-Band station are calibrated using the co-location comparison method. Then the signal biases of the other two CAPS C-Band stations, located in Linton and Kashi, are calibrated using the combined POD method, with the signal biases of the Changchun C-Band station being fixed. After the signal biases are calibrated, the RMS of the line-of-sight residuals of the Changchun SLR observations decrease by 04 m, with the percentage improvement being 75.19%.
WOS研究方向Engineering ; Oceanography
语种英语
出版者CAMBRIDGE UNIV PRESS
WOS记录号WOS:000386198300004
内容类型期刊论文
源URL[http://119.78.226.72/handle/331011/32737]  
专题中国科学院上海天文台
通讯作者Cao Fen
作者单位1.Chinese Acad Sci, Grad Univ, Beijing 100864, Peoples R China
2.Chinese Acad Sci, Natl Time Serv Ctr, Key Lab Precis Nav & Timing Technol, Beijing 100864, Peoples R China
3.Chinese Acad Sci, Natl Time Serv Ctr, Beijing 100864, Peoples R China
4.Chinese Acad Sci, Shanghai Astron Observ, Beijing 100864, Peoples R China
推荐引用方式
GB/T 7714
Cao Fen,Yang Xuhai,Li Zhigang,et al. Signal Biases Calibration for Precise Orbit Determination of the Chinese Area Positioning System using SLR and C-Band Transfer Ranging Observations[J]. JOURNAL OF NAVIGATION,2016,69(6):1234-1246.
APA Cao Fen,Yang Xuhai,Li Zhigang,Chen Liang,&Feng Chugang.(2016).Signal Biases Calibration for Precise Orbit Determination of the Chinese Area Positioning System using SLR and C-Band Transfer Ranging Observations.JOURNAL OF NAVIGATION,69(6),1234-1246.
MLA Cao Fen,et al."Signal Biases Calibration for Precise Orbit Determination of the Chinese Area Positioning System using SLR and C-Band Transfer Ranging Observations".JOURNAL OF NAVIGATION 69.6(2016):1234-1246.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace