Effective elimination of organic matter interference in boron isotopicanalysis by thermal ionization mass spectrometry of coral/foraminifera:micro-sublimation technology combined with ion exchange | |
He, Maoyong ; Jin, Zhangdong ; Xiao, Jun | |
刊名 | RAPID COMMUNICATIONS IN MASS SPECTROMETRY
![]() |
2011 | |
卷号 | 25期号:6页码:743-749 |
英文摘要 | In order to better estimate the effectiveness of micro-sublimation technology on the elimination of organic matter interference during boron isotopic analysis, a series of improved experiments was carried out using simple apparatus. Recovery rates after micro-sublimation were measured for boric acid solutions with different B contents or different B/organic matter ratios. The improved micro-sublimation procedure combined with ion-exchange technology was then used to test natural samples (coral and foraminifera) for the separation of boron. Our results show that the time taken for 100% recovery of different amounts of B differed and that the proportions of B/organic matter within the natural organic matter have little effect on the relationship between the recovery rates of B and the micro-sublimation times. The experiments further confirm that the organic matter does indeed have an effect on boron isotope analyses by positive thermal ionization mass spectrometry and that the use of micro-sublimation can effectively remove interferences from the organic matter during boron isotopic analysis. Copyright (C) 2011 John Wiley & Sons, Ltd. In order to better estimate the effectiveness of micro-sublimation technology on the elimination of organic matter interference during boron isotopic analysis, a series of improved experiments was carried out using simple apparatus. Recovery rates after micro-sublimation were measured for boric acid solutions with different B contents or different B/organic matter ratios. The improved micro-sublimation procedure combined with ion-exchange technology was then used to test natural samples (coral and foraminifera) for the separation of boron. Our results show that the time taken for 100% recovery of different amounts of B differed and that the proportions of B/organic matter within the natural organic matter have little effect on the relationship between the recovery rates of B and the micro-sublimation times. The experiments further confirm that the organic matter does indeed have an effect on boron isotope analyses by positive thermal ionization mass spectrometry and that the use of micro-sublimation can effectively remove interferences from the organic matter during boron isotopic analysis. Copyright (C) 2011 John Wiley & Sons, Ltd. |
收录类别 | SCI |
语种 | 英语 |
公开日期 | 2013-08-22 |
内容类型 | 期刊论文 |
源URL | [http://ir.isl.ac.cn/handle/363002/1880] ![]() |
专题 | 青海盐湖研究所_青海盐湖研究所知识仓储 中国科学院青海盐湖研究所 |
推荐引用方式 GB/T 7714 | He, Maoyong,Jin, Zhangdong,Xiao, Jun. Effective elimination of organic matter interference in boron isotopicanalysis by thermal ionization mass spectrometry of coral/foraminifera:micro-sublimation technology combined with ion exchange[J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY,2011,25(6):743-749. |
APA | He, Maoyong,Jin, Zhangdong,&Xiao, Jun.(2011).Effective elimination of organic matter interference in boron isotopicanalysis by thermal ionization mass spectrometry of coral/foraminifera:micro-sublimation technology combined with ion exchange.RAPID COMMUNICATIONS IN MASS SPECTROMETRY,25(6),743-749. |
MLA | He, Maoyong,et al."Effective elimination of organic matter interference in boron isotopicanalysis by thermal ionization mass spectrometry of coral/foraminifera:micro-sublimation technology combined with ion exchange".RAPID COMMUNICATIONS IN MASS SPECTROMETRY 25.6(2011):743-749. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。