Estimating the background count rate in the energy field from 0.55-2.75 MeV for Chang'E-1 gamma-ray spectrometer | |
Ma, T.![]() ![]() ![]() | |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
2012-02-01 | |
卷号 | 664期号:1页码:232-235 |
关键词 | Lunar Gamma-ray spectrometer Remote sensing Chang'E-1 Background |
ISSN号 | 0168-9002 |
英文摘要 | With a large geometrical area, the Gamma-ray spectrometer (GRS) onboard Chang'E-1 was designed to detect gamma rays from the moon. The scientific objective is to study the element information including both type and abundance by distinguishing the energy of gamma ray peak relative to elements and calculating the peak area counts. Regretfully, the cislunar spectrum of GRS was not collected. Nevertheless, we give a method to estimate the background count rate in the energy field from 0.55-2.75 MeV. A natural radioactivity count rate map in 2 degrees x 2 degrees grids is shown after reducing the background count rate and the uncertainty of the result is discussed. (C) 2011 Elsevier B.V. All rights reserved. |
学科主题 | Astronomy & Astrophysics |
WOS标题词 | Science & Technology ; Technology ; Physical Sciences |
类目[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy |
研究领域[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000299592000031 |
公开日期 | 2013-01-31 |
内容类型 | 期刊论文 |
源URL | [http://libir.pmo.ac.cn/handle/332002/7947] ![]() |
专题 | 紫金山天文台_暗物质和空间天文实验室 |
作者单位 | Purple Mt Observ, Nanjing 210008, Jiangsu, Peoples R China |
推荐引用方式 GB/T 7714 | Ma, T.,Chang, J.,Zhang, N.,et al. Estimating the background count rate in the energy field from 0.55-2.75 MeV for Chang'E-1 gamma-ray spectrometer[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2012,664(1):232-235. |
APA | Ma, T.,Chang, J.,Zhang, N.,&Wu, J..(2012).Estimating the background count rate in the energy field from 0.55-2.75 MeV for Chang'E-1 gamma-ray spectrometer.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,664(1),232-235. |
MLA | Ma, T.,et al."Estimating the background count rate in the energy field from 0.55-2.75 MeV for Chang'E-1 gamma-ray spectrometer".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 664.1(2012):232-235. |