Correlation between balloon release pressure and no-reflow in patients with acute myocardial infarction undergoing direct percutaneous coronary intervention
Wang Yanfei[1]; Yao Min[2]; Liu Haibo[3]; Yang Yuejin[4]; Xie Junmin[5]; Jia Xinwei[6]; Pan Huanjun[7]; Wang Chunyan[8]
刊名CHINESE MEDICAL JOURNAL
2014
卷号127期号:6页码:1008-1011
关键词acute myocardial infarction percutaneous coronary intervention balloon pressure no-reflow phenomenon
ISSN号0366-6999
DOIhttp://dx.doi.org/10.3760/cma.j.issn.0366-6999.20133002
URL标识查看原文
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/5079459
专题河北大学
作者单位1.[1]Hebei Univ, Affiliated Hosp, Dept Cardiovasc Dis, Baoding 071000, Hebei, Peoples R China.
2.[2]Chinese Acad Med Sci, Cardiovasc Inst, Dept Cardiovasc Dis, Beijing 100037, Peoples R China.,Chinese Acad Med Sci, Fu Wai Hosp, Beijing 100037, Peoples R China.,Peking Union Med Coll, Beijing 100037, Peoples R China.
3.[3]Chinese Acad Med Sci, Cardiovasc Inst, Dept Cardiovasc Dis, Beijing 100037, Peoples R China.,Chinese Acad Med Sci, Fu Wai Hosp, Beijing 100037, Peoples R China.,Peking Union Med Coll, Beijing 100037, Peoples R China.
4.[4]Chinese Acad Med Sci, Cardiovasc Inst, Dept Cardiovasc Dis, Beijing 100037, Peoples R China.,Chinese Acad Med Sci, Fu Wai Hosp, Beijing 100037, Peoples R China.,Peking Union Med Coll, Beijing 100037, Peoples R China.
5.[5]Hebei Univ, Affiliated Hosp, Dept Cardiovasc Dis, Baoding 071000, Hebei, Peoples R China.
6.[6]Hebei Univ, Affiliated Hosp, Dept Cardiovasc Dis, Baoding 071000, Hebei, Peoples R China.
7.[7]Hebei Univ, Affiliated Hosp, Dept Cardiovasc Dis, Baoding 071000, Hebei, Peoples R China.
8.[8]Hebei Univ, Affiliated Hosp, Dept Cardiovasc Dis, Baoding 071000, Hebei, Peoples R China.
推荐引用方式
GB/T 7714
Wang Yanfei[1],Yao Min[2],Liu Haibo[3],et al. Correlation between balloon release pressure and no-reflow in patients with acute myocardial infarction undergoing direct percutaneous coronary intervention[J]. CHINESE MEDICAL JOURNAL,2014,127(6):1008-1011.
APA Wang Yanfei[1].,Yao Min[2].,Liu Haibo[3].,Yang Yuejin[4].,Xie Junmin[5].,...&Wang Chunyan[8].(2014).Correlation between balloon release pressure and no-reflow in patients with acute myocardial infarction undergoing direct percutaneous coronary intervention.CHINESE MEDICAL JOURNAL,127(6),1008-1011.
MLA Wang Yanfei[1],et al."Correlation between balloon release pressure and no-reflow in patients with acute myocardial infarction undergoing direct percutaneous coronary intervention".CHINESE MEDICAL JOURNAL 127.6(2014):1008-1011.