The development of an evaluation method for capture columns used in two-dimensional liquid chromatography | |
Cao, Liwei1,2; Yu, Danhua1; Wang, Xinliang1; Ke, Yanxiong1; Jin, Yu1; Liang, Xinmiao1,2 | |
刊名 | analytica chimica acta |
2011-11-07 | |
卷号 | 706期号:1页码:184-190 |
关键词 | Capture column Evaluation method Two-dimensional liquid chromatography Separation materials |
ISSN号 | 待补充 |
通讯作者 | 金郁 ; 梁鑫淼 |
产权排序 | 2,1 |
中文摘要 | the development of an evaluation method for capture columns used in two-dimensional liquid chromatography |
英文摘要 | capture columns are important interface tools for on line two-dimensional liquid chromatography (2d-lc). in this study, a systematic method was developed to evaluate and optimize the capture ability of capture columns by off-line method. first, the parameter delta t(r) (delta t(r) = t(2)-t(1)-t(0)-w) was introduced to quantitatively represent the capture ability of the capture column by connecting a capture column behind the first dimensional column. based on the value of delta t(r), an appropriate capture column was selected after the first dimensional column was fixed. then, the capture ability of the selected column was promoted by adjusting the mobile phase of the first dimensional column. capture ability was also optimized using complex sample analysis software system (csass) software. second, the elution mode of the trapped compounds on the capture column was investigated by connecting the capture column before the second dimensional column. more specifically, in mode i. capture column was connected to the second dimension without changing the flow rate direction and the trapped compounds must pass through the capture column and be eluted into the second dimensional column. the contrary connection mode was mode ii. it was found that mode i is more suitable method for 2d-lc. finally, an off-line reversed-phase/hydrophilic interaction liquid chromatography two-dimensional liquid chromatography (rp/hilic 2d-lc) system with a c18 capture column was developed to demonstrate the practical application of this method. (c) 2011 elsevier b.v. all rights reserved. |
学科主题 | 物理化学 |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | reversed-phase ; mass-spectrometry ; performance ; separation ; system ; protein ; fractionation ; optimization ; pressure ; samples |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000296755300020 |
公开日期 | 2012-07-09 |
内容类型 | 期刊论文 |
源URL | [http://159.226.238.44/handle/321008/115349] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.E China Univ Sci & Technol, Sch Pharm, Minist Educ, Engn Res Ctr Pharmaceut Proc Chem, Shanghai 200237, Peoples R China 2.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China |
推荐引用方式 GB/T 7714 | Cao, Liwei,Yu, Danhua,Wang, Xinliang,et al. The development of an evaluation method for capture columns used in two-dimensional liquid chromatography[J]. analytica chimica acta,2011,706(1):184-190. |
APA | Cao, Liwei,Yu, Danhua,Wang, Xinliang,Ke, Yanxiong,Jin, Yu,&Liang, Xinmiao.(2011).The development of an evaluation method for capture columns used in two-dimensional liquid chromatography.analytica chimica acta,706(1),184-190. |
MLA | Cao, Liwei,et al."The development of an evaluation method for capture columns used in two-dimensional liquid chromatography".analytica chimica acta 706.1(2011):184-190. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论