英文摘要after reviewing the spectrum-dividing principle of the savart polariscope (sp) in the polarization interference imaging spectrometer (piis) that we developed, we analyze the influences of the thickness, misalignment, and dispersion of the sp on the optical path difference (opd). the theoretical expression of the opd for the misalignment of the sp optical axis is deduced, and the opd is analyzed when the incident plane is parallel, at 45 degrees, or orthogonal to the principal section of the left plate of the sp. the selective thickness of the single savart plate is analyzed when it is placed at the ideal and misalignment positions. the influence of dispersion of the sp on the opd is analyzed when the misalignment error is +/- 1'. the relationships between the opd and wavelength are simulated and validated with experiments. this work can provide theoretical and practical guidance for the design, calibration, modulation, innovation, experiment, and engineering of the piis. (c) 2011 optical society of america
WOS标题词science & technology ; physical sciences
类目[WOS]optics
研究领域[WOS]optics
关键词[WOS]upper atmospheric wind ; fourier-transform ; orientation
收录类别SCI ; EI
原文出处http://www.opticsinfobase.org/ao/abstract.cfm?uri=ao-50-20-3497
语种英语
WOS记录号WOS:000293069000016
公开日期2012-06-29
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/19852]  
专题西安光学精密机械研究所_检测技术研究中心
作者单位1.Xi An Jiao Tong Univ, Sch Sci, Minist Educ, Key Lab Nonequilibrium Synth & Modulat Condensed, Xian 710049, Peoples R China
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
3.Mindray Med Int Ltd, Shenzhen 518057, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Chunmin,Zhao, Jianke,Sun, Yao. Influences of the thickness, misalignment, and dispersion of the Savart polariscope on the optical path difference and spectral resolution in the polarization interference imaging spectrometer[J]. applied optics,2011,50(20):3497-3504.
APA Zhang, Chunmin,Zhao, Jianke,&Sun, Yao.(2011).Influences of the thickness, misalignment, and dispersion of the Savart polariscope on the optical path difference and spectral resolution in the polarization interference imaging spectrometer.applied optics,50(20),3497-3504.
MLA Zhang, Chunmin,et al."Influences of the thickness, misalignment, and dispersion of the Savart polariscope on the optical path difference and spectral resolution in the polarization interference imaging spectrometer".applied optics 50.20(2011):3497-3504.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace