CORC  > 大连理工大学
Experimental study on overall heat transfer coefficient of seawater on three tube arrangements for horizontal-tube falling film evaporator
Mu, Xingsen; Shen, Shengqiang; Yang, Yong; Liang, Gangtao; Chen, Xue; Zhang, Jili
刊名DESALINATION AND WATER TREATMENT
2016
卷号57页码:9993-10002
关键词Tube arrangement Seawater Overall heat transfer coefficient Horizontal-tube falling film Desalination
ISSN号1944-3994
URL标识查看原文
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/4368036
专题大连理工大学
作者单位1.Dalian Univ Technol, Sch Energy & Power Engn, Key Lab Liaoning Prov Desalinat, Dalian 116024, Liaoning, Peoples R China.
2.Dalian Univ Technol, Sch Civil Engn Dalian, Dalian 116024, Liaoning, Peoples R China.
推荐引用方式
GB/T 7714
Mu, Xingsen,Shen, Shengqiang,Yang, Yong,et al. Experimental study on overall heat transfer coefficient of seawater on three tube arrangements for horizontal-tube falling film evaporator[J]. DESALINATION AND WATER TREATMENT,2016,57:9993-10002.
APA Mu, Xingsen,Shen, Shengqiang,Yang, Yong,Liang, Gangtao,Chen, Xue,&Zhang, Jili.(2016).Experimental study on overall heat transfer coefficient of seawater on three tube arrangements for horizontal-tube falling film evaporator.DESALINATION AND WATER TREATMENT,57,9993-10002.
MLA Mu, Xingsen,et al."Experimental study on overall heat transfer coefficient of seawater on three tube arrangements for horizontal-tube falling film evaporator".DESALINATION AND WATER TREATMENT 57(2016):9993-10002.