CORC  > 金属研究所  > 中国科学院金属研究所
Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation
K. Zheng ; X. K. Li ; J. Fu ; X. L. Fan ; P. Wang ; Y. L. Hao ; S. J. Li ; H. B. Fan ; Z. Guo
刊名Journal of Materials Science-Materials in Medicine
2011
卷号22期号:6页码:1579-1588
关键词skeletal fixation stainless-steel tract infection schanz screws bone complications strength fractures interface movement
ISSN号0957-4530
中文摘要The objective of this study was to compare the benefits of titanium 2448 (Ti2448) half-pin and titanium-6 aluminium-4 vanadium (TAV) half-pin on reducing pin loosening during external fracture fixation. Although having similar strength, Ti2448 half-pin had even lower elastic modules(33 GPa) when compared with TAV half-pin (110 GPa), which was similar to that of cortical bone (20 GPa). In the external fixation of tibial model fractures and canine cadaveric tibia fractures, Ti2448 half-pin had greater recoverable deformation and less stress concentration at the pin-bone interface in compression, torsion, and four-points bending test. Then, tibial fractures were created in 24 dogs and stabilized with four half-pins of either Ti2448 or TAV in each animal. At 4 and 8 weeks post-operatively, fracture healing and pin loosening was assessed by radiographic grading scale. The scores of Ti2448 group were significantly higher than those of TAV group. Micro-CT analysis also indicated larger quantity and higher quality of newly formed bone at pin-bone interface in Ti2448 group. Histology observation showed the newly formed bone integrated well into the threads of Ti2448 half-pins. In contrast, there was a layer of necrotic tissue between the bone tissue and TAV half-pin at pin-bone interface in TAV group. The extraction torque values of Ti2448 half-pins near the fracture line were significantly higher than those TAV pins. In conclusion, the Ti2448 half-pin with low elastic modulus could enhance osseointegration and reduce pin loosening when compared with TAV half-pin. It is a promising biomaterial for constructing external fixation system in clinical application.
原文出处://WOS:000291702500021
公开日期2012-04-13
内容类型期刊论文
源URL[http://210.72.142.130/handle/321006/30963]  
专题金属研究所_中国科学院金属研究所
推荐引用方式
GB/T 7714
K. Zheng,X. K. Li,J. Fu,et al. Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation[J]. Journal of Materials Science-Materials in Medicine,2011,22(6):1579-1588.
APA K. Zheng.,X. K. Li.,J. Fu.,X. L. Fan.,P. Wang.,...&Z. Guo.(2011).Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation.Journal of Materials Science-Materials in Medicine,22(6),1579-1588.
MLA K. Zheng,et al."Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation".Journal of Materials Science-Materials in Medicine 22.6(2011):1579-1588.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace