英文摘要A fast and sensitive ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) method was developed for simultaneously analyzing 10 phthalates in perfume, which are forbidden by the hygienic standards for cosmetics in China (2007 edition). Matrix effect is significant on a phthalate when it is co-eluted with other phthalates. Improving the resolution between adjacent phthalate peaks is found effective in reducing the matrix effects. Thus, simultaneous analysis of the 10 phthalates requires successful resolutions of each phthalate. Nonetheless, a trade-off between the resolution and analysis time results either incomplete separation or prolonged analysis time. Here, the UHPLC elution gradient is optimized considering the predicted retention time of each phthalate. The resolutions and matrix effects of targeted compounds are evaluated to determine the optimal elution gradient for UHPLC-MS analysis method. Under the optimized gradient, the resolution between closest phthalate peaks is beyond 1.7, while the analysis time is merely 7 min. Except for dimethyl phthalate (DMP) and dicyclohexyl phthalate (DCHP), insignificant matrix effects have been found on all the phthalates. Direct quantifications through external calibration curve are appropriate for such analytes. Nonetheless, DMP and DCHP suffering obvious matrix effects require extra analyses of spiked samples for the quantifications through the standard addition method. Instrumental limits of quantitation (iLOQs) are 0.12-89 mu g L-1 for the targeted phthalates. Meanwhile, the accuracy and precision of the analytical method are good. Finally, the forbidden phthalates in 26 sampled perfumes are successfully analyzed by the developed method. (C) 2018 Elsevier B.V. All rights reserved.
内容类型期刊论文
源URL[http://210.75.249.4/handle/363003/59935]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
推荐引用方式
GB/T 7714
Wei, Xue-Bing,Li, Ruo-Qi,Yu, Han,et al. Fast and sensitive determination of 10 forbidden phthalates in perfumes by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry[J]. JOURNAL OF CHROMATOGRAPHY A,2018,1578.
APA Wei, Xue-Bing,Li, Ruo-Qi,Yu, Han,&Wang, Ren-Qi.(2018).Fast and sensitive determination of 10 forbidden phthalates in perfumes by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,1578.
MLA Wei, Xue-Bing,et al."Fast and sensitive determination of 10 forbidden phthalates in perfumes by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 1578(2018).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace