Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation
Fan, YK (Fan, Yukun)[ 1,2,3 ]; Fu, YC (Fu, Yunchong)[ 1,2 ]; Zhang, LY (Zhang, Luyuan)[ 1,2 ]; Hou, XL (Hou, Xiaolin)[ 1,2 ]; Zhou, WJ (Zhou, Weijian)[ 1,2,4 ]; Liu, Q (Liu, Qi)[ 1,2,3 ]; Chen, N (Chen, Ning)[ 1,2 ]; Luo, MY (Luo, Maoyi)[ 2,4 ]
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS
2013-01-30
卷号294页码:276-280
关键词Iodine-129 Carrier Free Coprecipitation Ams Minimum Sample Amount Detection Limit
DOI10.1016/j.nimb.2012.06.023
文献子类期刊论文
英文摘要

I-129 has been successfully applied as tracer in environmental, geological, and oceanographic research. For samples with low stable iodine concentration and ultra low level I-129, the sample preparation technique to separate iodine prior to AMS measurement has been a bottleneck, limiting the applicability of I-129 We have reported a carrier-free method, using coprecipitation, to avoid the potential introduction of I-129 through the use of stable iodine carrier iodine. In this work, the detection limit and the analytical uncertainty of this method are investigated and minimum sample amount required to obtain reliable analytical results are estimated. The method is validated with a series of samples in ranges of known iodine concentrations and I-129/I-127 ratios. The results confirm our previous conclusion that an AMS target containing 5.0 mu g iodine can be used for analyzing samples with I-129/I-127 > 10(-12), and that for samples with I-129/I-127 < 10(-13) more than 25 mu g iodine is necessary.

语种英语
内容类型期刊论文
源URL[http://ir.ieecas.cn/handle/361006/10051]  
专题地球环境研究所_加速器质谱中心
通讯作者Hou, XL (Hou, Xiaolin)[ 1,2 ]
作者单位1.SKLLQG, Institute of Earth Environment, China Academy of Sciences, Xi’an 710075, China;
2.Xi’an AMS Center, Xi’an 710061, China;
3.Graduate University of the Chinese Academy of Science, Beijing 100049, China;
4.Xi’an JiaoTong University, Xi’an 710049, China
推荐引用方式
GB/T 7714
Fan, YK ,Fu, YC ,Zhang, LY ,et al. Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,2013,294:276-280.
APA Fan, YK .,Fu, YC .,Zhang, LY .,Hou, XL .,Zhou, WJ .,...&Luo, MY .(2013).Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS,294,276-280.
MLA Fan, YK ,et al."Performance of Accelerator Mass Spectrometry for I-129 using AgI-AgCl carrier-free coprecipitation".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS 294(2013):276-280.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace