A 2.45 GHz intense proton source and low energy beam transport system for China Initiative Accelerator Driven Sub-Critical reactor system
Yang, Y7; Ma, HY7; Cao, Y7; Zhang, XZ7; Wu, Q (reprint author), Chinese Acad Sci, IMP, Lanzhou 730000, Peoples R China.; Zhao, HW7; Sun, LT7; Zhang, ZM7; Wu, Q7
刊名REVIEW OF SCIENTIFIC INSTRUMENTS
2014
卷号85页码:-
ISSN号0034-6748
DOI10.1063/1.4824804
英文摘要At Institute of Modern Physics, a cw 35 keV, 20 mA intense proton source and the low energy beam transport system (LEBT) have been developed for China Initiative Accelerator Driven Sub-Critical reactor system. In order to ensure high quality transmission of the intense ion beam from the exit of ion source to Radio Frequency Quadrupole (RFQ), a low energy beam transport line is used to focus beam to the RFQ entrance and match the Twiss parameters to the RFQ requirements. The 35 keV, 20 mA ion beam extracted by a three-electrode extraction system from the ion source passes through the LEBT to the RFQ entrance and the root-mean-square emittance is measured to be less than 0.2 pi mm mrad. The commissioning results of the ion source and low energy beam transport system are described in this paper. The beam quality and transmission efficiency are also studied. (c) 2013 AIP Publishing LLC.
WOS研究方向Instruments & Instrumentation ; Physics
语种英语
出版者AMER INST PHYSICS
WOS记录号WOS:000335919900015
内容类型期刊论文
源URL[http://ir.impcas.ac.cn/handle/113462/23530]  
专题近代物理研究所_兰州重离子研究装置
通讯作者Wu, Q (reprint author), Chinese Acad Sci, IMP, Lanzhou 730000, Peoples R China.
作者单位1.Yang, Y.
2.Ma, H. Y.
3.Cao, Y.
4.Zhang, X. Z.
5.Zhao, H. W.] Chinese Acad Sci, IMP, Lanzhou 730000, Peoples R China
6.[Yang, Y.] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
7.[Wu, Q.
8.Zhang, Z. M.
9.Sun, L. T.
推荐引用方式
GB/T 7714
Yang, Y,Ma, HY,Cao, Y,et al. A 2.45 GHz intense proton source and low energy beam transport system for China Initiative Accelerator Driven Sub-Critical reactor system[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2014,85:-.
APA Yang, Y.,Ma, HY.,Cao, Y.,Zhang, XZ.,Wu, Q .,...&Wu, Q.(2014).A 2.45 GHz intense proton source and low energy beam transport system for China Initiative Accelerator Driven Sub-Critical reactor system.REVIEW OF SCIENTIFIC INSTRUMENTS,85,-.
MLA Yang, Y,et al."A 2.45 GHz intense proton source and low energy beam transport system for China Initiative Accelerator Driven Sub-Critical reactor system".REVIEW OF SCIENTIFIC INSTRUMENTS 85(2014):-.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace