Phase and Amplitude Stabilization System of Cavity Electric Field for HIRFL
Gao Yihai; Li Qiang; Lin Xinglong; Xu Zhe; Wang Chunxiao; Li Jing; Ci Guohui
刊名Nuclear Physics Review
2013
卷号30页码:425-429
ISSN号1007-4627
英文摘要The phase and amplitude stabilization system of high-frequency voltage on the main cyclotron SSC of Heavy Ion Research Facility in Lanzhou (HIRFL) is introduced. The system composition, negative feedback loop design and other important aspects about the development of the system are particularly presented in this paper. Designing method of digital PLL orthogonal transformation and loop filter of phase and amplitude stabilization are introduced in detail. Control systems of SSC have been tested through a long-term stability experiments, the test method of the parasitic modulation suppression and stabilization in long term is proposed. According to the analyzing data, it shows that phase control accuracy in long term is within 0.014° and the amplitude deviation in long term is lower than 1.29 * 10~(-4). Compared with the traditional system, its capability and target is much better.
CSCD记录号CSCD:5024872
内容类型期刊论文
源URL[http://119.78.100.186/handle/113462/59898]  
专题近代物理研究所_兰州重离子研究装置
近代物理研究所_生物物理研究室
推荐引用方式
GB/T 7714
Gao Yihai,Li Qiang,Lin Xinglong,et al. Phase and Amplitude Stabilization System of Cavity Electric Field for HIRFL[J]. Nuclear Physics Review,2013,30:425-429.
APA Gao Yihai.,Li Qiang.,Lin Xinglong.,Xu Zhe.,Wang Chunxiao.,...&Ci Guohui.(2013).Phase and Amplitude Stabilization System of Cavity Electric Field for HIRFL.Nuclear Physics Review,30,425-429.
MLA Gao Yihai,et al."Phase and Amplitude Stabilization System of Cavity Electric Field for HIRFL".Nuclear Physics Review 30(2013):425-429.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace