关键词700 Μa O6++ Agor Cyclotron
英文摘要This paper reports on work performed during the last
two years to improve the performance of the KVI-AECR
ion source, which is used as an injector for the AGOR
cyclotron. We have installed stainless-steel screens at the
injection and extraction sides and an additional collar
around the extraction aperture resulting in better plasma
stability and an increase of extracted ion currents. Source
tuning is aided by continuously observing the visible light
output of the plasma through the extraction aperture with
a CCD camera. We now routinely extract 700 μA of O6+
ions and 50 μA of Pb27+ ions.
Source optimization is supported by extensive
computational modelling of the ion transport in the lowenergy
beam line and measuring the transverse emittance
of the extracted ion beam with a pepperpot emittance
meter. These efforts have shown that second-order
aberrations in the analyzing magnet lead to a significant
increase of the effective beam emittance. Work is
underway to compensate these aberrations.
会议录The 19th International Conference on Cyclotrons and their Applications, CYCLOTRONS'10
资助机构IMP;Chinese Academy of Sciences
语种英语
URL标识查看原文
内容类型会议论文
源URL[http://ir.imp.cas.cn/handle/113462/8511]  
专题近代物理研究所_近代物理研究所知识存储(2010之前)
推荐引用方式
GB/T 7714
V. Mironov,J.P.M. Beijers,S. Brandenburg,et al. ECRIS DEVELOPMENT AT KVI*[C]. 见:. Lanzhou. 2010-09-06.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace