RF voltage amplitude stability system of the injector of HIRFL
Zhao, Jianming; Gao, Yihong; Li, Zhengqin
刊名Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams
1996
卷号8页码:279-285
ISSN号1001-4322
其他题名加速器高频幅度稳定系统
英文摘要Amplitude stability system of the 200kw RF generator had been completed and successfully used in the injector (SFC) of HIRFL. The system can be equivalent to a negative feed-back circuit, which stabilizes the RF voltage of the cyclotron at rate of 1.7×10-4, so that the extraction efficiency and energy spread of the beam can be improved.