Room-temperature test system for 162.5 MHz high-power couplers | |
Chen, Long1,2; Zhang, Shen-Hu2; Li, Yong-Ming2; Wang, Ruo-Xu2![]() ![]() ![]() ![]() | |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES
![]() |
2019-01 | |
卷号 | 30 |
关键词 | Couplers conditioning Test stand LLRF control system Test cavity |
ISSN号 | 1001-8042 |
DOI | 10.1007/s41365-018-0531-9 |
英文摘要 | Fundamental power couplers are crucial components for feeding radio frequency power to accelerating cavities. Couplers must be tested and conditioned on a room-temperature test stand to evaluate and potentially improve their performance before being installed in an accelerating cavity. A new test system has been designed and is under construction at the institute of modern physics. For this test system, multiple conditioning modes, including the pulse mode, CW mode, and amplitude-sweeping mode, have been embedded in the low-level radio frequency system of the test stand. All of these conditioning modes can be run manually or automatically. In addition, a novel test cavity is proposed and has been designed, which facilitates non-contact conditioning and a multi-purpose test stand. |
资助项目 | National Key Basic Research Program of China (973 Program)[2014CB845504] |
WOS关键词 | INPUT COUPLER ; CAVITIES |
WOS研究方向 | Nuclear Science & Technology ; Physics |
语种 | 英语 |
出版者 | SPRINGER SINGAPORE PTE LTD |
WOS记录号 | WOS:000455052000008 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.186/handle/113462/64491] ![]() |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Chen, Long |
作者单位 | 1.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 2.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Long,Zhang, Shen-Hu,Li, Yong-Ming,et al. Room-temperature test system for 162.5 MHz high-power couplers[J]. NUCLEAR SCIENCE AND TECHNIQUES,2019,30. |
APA | Chen, Long.,Zhang, Shen-Hu.,Li, Yong-Ming.,Wang, Ruo-Xu.,Jiang, Tiancai.,...&He, Yuan.(2019).Room-temperature test system for 162.5 MHz high-power couplers.NUCLEAR SCIENCE AND TECHNIQUES,30. |
MLA | Chen, Long,et al."Room-temperature test system for 162.5 MHz high-power couplers".NUCLEAR SCIENCE AND TECHNIQUES 30(2019). |