CORC  > 近代物理研究所  > 中国科学院近代物理研究所
Development of PMT high voltage control system for LASCAR detector array at RIBLL
Wu, Li-Jie; Wang, Jin-Chuan; Xiao, Guo-Qing; Guo, Zhong-Yan; Qi, Hui-Rong; Xu, Zhi-Guo; Zhang, Li; Ding, Xian-Li; Zhan, Wen-Long; Xu, Hu-Shan
刊名Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology
2005
卷号25页码:522-524+521
ISSN号0258-0934
英文摘要It is described in this paper that the multi-channel PMT high voltage power supply control system, which matches with the PMT high voltage module CC123 of the LASCAR detector array at RIBLL experiment terminal. The MCU AT89C51 is selected as the central control part and other suitable accessories are also adopted in our design. The PMT control system of the detector array works steadily and effectively in our performance test of LASCAR detector array.
出版者Atomic Energy Press, Beijing, China
内容类型期刊论文
源URL[http://119.78.100.186/handle/113462/64229]  
专题中国科学院近代物理研究所
作者单位1.Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
2.Graduate School, Chinese Academy of Sciences, Beijing 100049, China
3.School of Physics, Peking University, Beijing 100871, China
推荐引用方式
GB/T 7714
Wu, Li-Jie,Wang, Jin-Chuan,Xiao, Guo-Qing,et al. Development of PMT high voltage control system for LASCAR detector array at RIBLL[J]. Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology,2005,25:522-524+521.
APA Wu, Li-Jie.,Wang, Jin-Chuan.,Xiao, Guo-Qing.,Guo, Zhong-Yan.,Qi, Hui-Rong.,...&Li, Chen.(2005).Development of PMT high voltage control system for LASCAR detector array at RIBLL.Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology,25,522-524+521.
MLA Wu, Li-Jie,et al."Development of PMT high voltage control system for LASCAR detector array at RIBLL".Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology 25(2005):522-524+521.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace