Alignment of beam position monitors in cryomodule of CADS injector II | |
Yuan, Jian-Dong; He, Yuan; Zhang, Bin; Zhang, Jun-Hui; Wu, Jun-Xia; Zhang, Yong; Wang, Feng-Feng; Yao, Jun-Jie; Sun, Guo-Zhen; Wan, Yu-Qin | |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES |
2017-06-01 | |
卷号 | 28页码:6 |
关键词 | Beam position monitors Alignment Fourier's Law Cryomodule CADS ANSYS |
ISSN号 | 1001-8042 |
DOI | 10.1007/s41365-017-0232-9 |
英文摘要 | Significant temperature difference (300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors (BPMs), which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations. In this paper, to check the offset from the mechanical to electrical center in low temperature (77 K), Fourier's law and finite element method are used to simulate cryo-deformation. Laser tracker and micro-alignment telescope are employed in combined BPM calibration, installation and monitoring. The calibration error is <0.02 mm, and the installation and monitoring precision are 0.06 mm and 0.01 mm, respectively. The monitored cryo-deformation agrees well with the simulation results. These indicate that the combined alignment can improve performance of the BPM system. All these guaranteed the success of running the 9.55 MeV@ 2.14 mA cw protons. |
资助项目 | National Natural Science Foundation of China[11605262] |
WOS研究方向 | Nuclear Science & Technology ; Physics |
语种 | 英语 |
出版者 | SPRINGER SINGAPORE PTE LTD |
WOS记录号 | WOS:000402895400003 |
资助机构 | National Natural Science Foundation of China |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.186/handle/113462/44889] |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Yuan, Jian-Dong |
作者单位 | Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Yuan, Jian-Dong,He, Yuan,Zhang, Bin,et al. Alignment of beam position monitors in cryomodule of CADS injector II[J]. NUCLEAR SCIENCE AND TECHNIQUES,2017,28:6. |
APA | Yuan, Jian-Dong.,He, Yuan.,Zhang, Bin.,Zhang, Jun-Hui.,Wu, Jun-Xia.,...&Wan, Yu-Qin.(2017).Alignment of beam position monitors in cryomodule of CADS injector II.NUCLEAR SCIENCE AND TECHNIQUES,28,6. |
MLA | Yuan, Jian-Dong,et al."Alignment of beam position monitors in cryomodule of CADS injector II".NUCLEAR SCIENCE AND TECHNIQUES 28(2017):6. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论