Polarization Characterization of Laser-Induced Fluorescence from the Simulated Oil Samples Based on Polar Decomposition of Mueller Matrix | |
Luan Xiao-ning1; Zhang Feng1; Guo Jin-jia1; Cui Ting-wei2; Zheng Rong-er1 | |
刊名 | SPECTROSCOPY AND SPECTRAL ANALYSIS |
2018-02 | |
卷号 | 38期号:2页码:467-474 |
关键词 | Oil spills Laser induced fluorescence Polarization Mueller matrix |
ISSN号 | 1000-0593 |
DOI | 10.3964/j.issn.1000-0593(2018)02-0467-08 |
英文摘要 | By refering to the principle and structure of the Mueller matrix ellipsometry, a LIF ellipsometric setup with rotating waveplate was built up to investigate the polarization characterization of laser-induced fluorescence from the simulated oil spill samples under excitation of laser with different elliptical polarization states. The setup was calibrated with the Eigenvalue Calibration Method at first to obtain the exact modulation states of both the polarization modulation matrix W(lambda) and the polarization analyses matrix A(lambda). Then with the fluorescence intensity matrices Flu(lambda) measured by sequentially modulation of the polarization-state generator unit and the polarization-state analyzer unit, LIF Mueller matrices of light, medium and heavy crude oil samples as well as diesel were established and analyzed via polar decomposition. It was found that the depolarization properties of fluorescence spectrum from different samples were of significant differences. The depolarization coefficient extracted from the LIF Mueller matrix from diesel varied little with the wavelength increasing, which maintained a high degree of depolarization value within the whole spectral range, while those from other three crude samples kept rising under the same circumstances. With respect to the variation amplitude of the depolarization coefficient, the medium crude sample exceeded the heavy crude but was inferior to the light one. Among the four simulated oil samples, the depolarization coefficient extracted from LIF Mueller matrices from light crude and heavy crude samples were highest and lowest respectively, while those from diesel and medium samples lied between them. Compared to the results of LIF orthogonal polarization experiment under linearly polarized excitation, the depolarization coefficients Delta(lambda) extracted from polar decomposition of LIF Mueller matrices were highly relevant to those DODP obtained from orthogonal polarization characterization of fluorescence spectrum of the simulated oil samples. And it was also found that both the diattenuation and retardation properties of the fluorescence spectrum from the simulated oil samples were very weak and showed little differences. |
WOS关键词 | SPILL ; FLUOROSENSORS |
WOS研究方向 | Spectroscopy |
语种 | 中文 |
出版者 | OFFICE SPECTROSCOPY & SPECTRAL ANALYSIS |
WOS记录号 | WOS:000426142100022 |
内容类型 | 期刊论文 |
源URL | [http://ir.fio.com.cn:8080/handle/2SI8HI0U/26500] |
专题 | 自然资源部第一海洋研究所 |
通讯作者 | Zheng Rong-er |
作者单位 | 1.Ocean Univ China, Opt & Optoelect Lab, Qingdao 266100, Peoples R China 2.State Ocean Adm, Inst Oceanog 1, Qingdao 266061, Peoples R China |
推荐引用方式 GB/T 7714 | Luan Xiao-ning,Zhang Feng,Guo Jin-jia,et al. Polarization Characterization of Laser-Induced Fluorescence from the Simulated Oil Samples Based on Polar Decomposition of Mueller Matrix[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2018,38(2):467-474. |
APA | Luan Xiao-ning,Zhang Feng,Guo Jin-jia,Cui Ting-wei,&Zheng Rong-er.(2018).Polarization Characterization of Laser-Induced Fluorescence from the Simulated Oil Samples Based on Polar Decomposition of Mueller Matrix.SPECTROSCOPY AND SPECTRAL ANALYSIS,38(2),467-474. |
MLA | Luan Xiao-ning,et al."Polarization Characterization of Laser-Induced Fluorescence from the Simulated Oil Samples Based on Polar Decomposition of Mueller Matrix".SPECTROSCOPY AND SPECTRAL ANALYSIS 38.2(2018):467-474. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论