CORC  > 北京大学  > 信息科学技术学院
Evalution of Bulk Titanium DRIE Using SU-8 As Soft Mask
Zhao, Gang ; Tian, Yao ; Shu, Qiong ; Chen, Jing
2009
关键词Titanium DRIE SU-8 softmask profile
英文摘要This paper reports the characterization of bulk titanium deep etching using inductively coupled chlorine plasma using SU-8 as softmask. SU-8 has many advantages over the traditional employed hardmask, such as selective stripping, cost efficiency and the ability to accommodate ultra deep etching. The effects of process parameters (ICP source power, platen power and Cl(2) flow rate) on etch rate, selectivity and the etch profile were investigated. With the optimized process parameters (400 W ICP source power, 100 W platen power, 60 Seem 02 flow rate, 3 mT chamber pressure), an etch rate of 1.06 mu m/min has been achieved with an aspect ratio of 5:1 and smooth surface. Ultra-deep titanium etching up to 200 mu m has been realized with SU-8 softmask, which is among the best or the present reports.; http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000273161500119&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701 ; Engineering, Electrical & Electronic; Nanoscience & Nanotechnology; EI; CPCI-S(ISTP); 0
语种英语
DOI标识10.1109/NEMS.2009.5068631
内容类型其他
源URL[http://ir.pku.edu.cn/handle/20.500.11897/153271]  
专题信息科学技术学院
推荐引用方式
GB/T 7714
Zhao, Gang,Tian, Yao,Shu, Qiong,et al. Evalution of Bulk Titanium DRIE Using SU-8 As Soft Mask. 2009-01-01.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace