Research of Resonant Frequency and Quality Factor Test Methods for High Vacuum Sealed Microgyroscope Based on LabVIEW | |
Yan, Junjie ; He, Chunhua ; Ge, Fei ; Zhao, Qiancheng ; Cui, Jian ; Yan, Guizhen | |
2011 | |
关键词 | high vacuum sealed microgyroscope quality factor resonant frequency LabVIEW |
英文摘要 | In this paper, we demonstrate an efficient and precise method for measuring the resonant frequency and quality factor of high vacuum sealed microgyroscope based on the free vibration theory with NI platform. A comparison is carried out between the proposed method and the conventional sweep-frequency test method. Experiments indicate that the results obtained by these two methods are nearly the same for the low-Q (<2000) sealed gyroscopes. However, as for the high-Q (>50000) sealed gyroscopes, the consecutive-test-error and test-period of quality factor with sweep-frequency test method and the free vibration test method are about 2000, 10 minutes and 500, 5 seconds, respectively. Furthermore, sweep-frequency method extremely depends on experience while vibration method hardly does. The automatic test method based on vibration theory can much enhance the accuracy and efficiency of the performance test for high vacuum sealed gyroscope. (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of [CEIS 2011]; Automation & Control Systems; CPCI-S(ISTP); 0 |
语种 | 英语 |
DOI标识 | 10.1016/j.proeng.2011.08.482 |
内容类型 | 其他 |
源URL | [http://ir.pku.edu.cn/handle/20.500.11897/153247] ![]() |
专题 | 信息科学技术学院 |
推荐引用方式 GB/T 7714 | Yan, Junjie,He, Chunhua,Ge, Fei,et al. Research of Resonant Frequency and Quality Factor Test Methods for High Vacuum Sealed Microgyroscope Based on LabVIEW. 2011-01-01. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论